Summary of Contents for NovoFold

Page 1: ...NovoFold Gebrauchsanleitung Falt Schnelllauftor NovoFold User Manual High Speed Stacking Door NovoFold Manual d utilisation Porte Rapide Autor parable NovoFold Manual de uso Puerta R pida Autoreparab...

Page 2: ...ruikershandleiding NovoFold Nederlands REVISIETABEL revisions table Nr Datum Uitgevoerd door Gereviseerd door Goedgekeurd door Opmerkingen 01 02 02 2017 A R P H A L I L T 04 05 08 2019 H A L H A L I L...

Page 3: ...eur door middel van een drukknoppaneel afstandsbediening 5 4 A 2 Werking van de deur in de modus Persoon aanwezig 7 4 A 3 Gebruik van de noodhandbediening 8 5 VEILIGHEID 9 6 STORINGEN 10 7 CONFORMITEI...

Page 4: ...uiker van de deur en moet in de buurt van de deur worden bewaard Instrueer de gebruikers hoe ze de snelle stapeldeur moeten bedienen Laat de deur niet door derden bedienen Voordat u de deur voor de ee...

Page 5: ...toriseerd bediend en er is een systeem ge nstalleerd om in geval van een storing of uitval van de motor over te schakelen naar de handmatige modus Op onderstaande afbeelding staan de belangrijkste ond...

Page 6: ...l is aangegeven moet er een uitgebreider onderhoud worden uitgevoerd dan in eerste instantie wordt aanbevolen Neem in dit geval contact op met de fabrikant om een inschatting te maken van de meest ges...

Page 7: ...iddel van een drukknoppaneel afstandsbediening Deze deur wordt ge nstalleerd op plaatsen waar een hoge openingssnelheid vereist is tot 1 m s dus de bediening moet altijd gemotoriseerd zijn Figuur 3 Dr...

Page 8: ...en van deze tijd wordt de deur gesloten mits de veiligheidsonderdelen dit toelaten Wanneer tijdens de sluitbeweging het drukknoppaneel de afstandsbediening of een veiligheidsonderdeel fotocel onderloo...

Page 9: ...e moment een veiligheidsonderdeel is geactiveerd fotocel onderloopbeveiliging zal de deur pas sluiten als dit veiligheidsonderdeel wordt vrijgegeven 4 A 2 Werking van de deur in de modus persoon aanwe...

Page 10: ...u de zwengel loslaat Doet u dit niet dan zal de deur abrupt sluiten LET OP In geen geval mag de deur worden ontgrendeld zonder dat eerst de stroomtoevoer wordt onderbroken Figuur 15 Detail van het ont...

Page 11: ...ectieafstand van 12 m ideaal voor gebieden waar er veel stof of weersomstandigheden zijn die de detectieafstand kunnen be nvloeden Er zijn ook andere optioneel verkrijgbare systemen om het risico tot...

Page 12: ...troomtoevoer is niet aangesloten Sluit de stroomtoevoer aan Fout Controleer de foutcode op het bedieningsscherm Bekijk of deze kan worden opgelost Is dit niet het geval neem dan contact op met de tech...

Page 13: ...Richtlijn 2014 30 EU De volgende geharmoniseerde Norm is toegepast EN 13241 Industriedeuren Productnorm De overeenkomstigheid werd gecontroleerd door LGAI Technological Centre SA Notified Body 0370 C...

Page 14: ...3 4 5 6 7 8 9 10 11 Controlelijst Locatie van de deur Deurplaat goedgekeurd 1 Conditie deurplaat 2 Bevestiging aan deurwals 3 Bevestiging onderbalk 4 Lasnaden in deurplaat 5 Bevestiging kogels 6 Verst...

Page 15: ...m monteur Handtekening monteur Verklaring monteur en of montagefirma Firmastempel Besturing goedgekeurd 25 Drukknoppen op de kast 26 Stop schakelaar 27 Bekabeling algemeen Bediendingen goedgekeurd 28...

Page 16: ...Gebrauchsanleitung NovoFold Deutsch NDERUNGEN Revisions table N Datum Bearbeitet von Gepr ft von Genehmigt von Bemerkungen 01 02 02 2017 A R P H A L I L T 04 05 08 2019 H A L H A L I L T...

Page 17: ...ION 19 4 A 1 Torbedienung mit Taster oder Fernbedienung 19 4 A 2 Torbetrieb TOTMANN 21 4 A 3 Handbedienung durch Notfallbediener 22 5 SICHERHEITSMASSNAHMEN 23 6 ST RUNGEN 24 7 KONFORMIT TSERKL RUNG 25...

Page 18: ...n N he aufbewahrt werden Die Benutzer sind in die Bedienung des stapelbaren Schnelllauftors einzuweisen Erlauben Sie nicht das Tor von Dritten bedienen zu lassen Bevor Sie das Tor zum ersten Mal bedie...

Page 19: ...as Tor wird immer motorisch betrieben wobei das System daf r sorgt dass es bei Motorausfall oder St rungen auf Handbetrieb umschaltet Das folgende Bild zeigt die Hauptbaugruppen des Tores Abbildung 1...

Page 20: ...e oben angegebenen berschreiten ist eine gr ndlichere Wartung als urspr nglich empfohlen durchzuf hren Wenden Sie sich dazu an den Hersteller um die f r diese Anwendung am besten geeignete Wartung zu...

Page 21: ...enung mit Taster oder Fernbedienung Dieses Tor ist dort eingebaut wo eine hohe ffnungsgeschwindigkeit bis zu 1 m s ben tigt wird Deswegen erfolgt der Betrieb immer motorisch Abbildung 3 Externe Druckt...

Page 22: ...e usw ausl st stoppt das Tor und ffnet wieder Automatischer Betrieb Schlie en nach Zeitablauf Durch Dr cken der Taster oder der Fernbedienung wird das Tor ge ffnet und bleibt offen bis die programmier...

Page 23: ...tseinrichtung ausgel st Lichtschranke untere Sicherheitsschaltleiste schlie t das Tor erst wenn die Sicherheitseinrichtung diese Funktion freigibt 4 A 2 Torbetrieb TOTMANN Der Vor Ort Betrieb Totmann...

Page 24: ...or dem Loslassen der Kurbel Bremse unbedingt wieder einrasten lassen Sonst w rde das Tor auf einmal herunter fallen ACHTUNG Niemals das Tor entsperren ohne den Strom vorher abzuschalten Abbildung 15 D...

Page 25: ...zum Boden befindet Die Erfassungsreichweite von 12 m ist ideal f r Bereiche in denen Staub oder Witterungseinfl sse die Erkennungsweite beeinflussen k nnen Es gibt andere optional einsetzbare Systeme...

Page 26: ...ffnet schlie t nicht Die Stromversorgung fehlt Die Stromversorgung anschlie en Fehler Das Fehlerprotokoll an der Torsteuerung auslesen Wenn dies nicht hilft wenden Sie sich an den technischen Service...

Page 27: ...ende harmonisierte Norm wurde angewandt EN 13241 Industrietore Produktnorm Die bereinstimmung wurde von folgender anerkannten Instanz kontrolliert LGAI Technological Centre SA Notified Body 0370 Campu...

Page 28: ...Tors Torschild genehmigt 1 Zustand des Torblatts 2 Befestigung an der Laufrolle 3 Befestigung am unteren Tr ger 4 Schwei n hte am Torblatt 5 Befestigung der Kugeln 6 Verst rkungsprofile Unterer Tr ge...

Page 29: ...erschrift des Technikers Erkl rung des Technikers und oder der Installationsfirma Firmenstempel Steuerung genehmigt 25 Drucktasten am Kasten 26 Stoppschalter 27 Allgemeine Verkabelung Betrieb genehmig...

Page 30: ...User manual NovoFold English Revisions table N Date Prepared by Checked by Approved by Comments 01 02 02 2017 A R P H A L I L T 04 05 08 2019 H A L H A L I L T...

Page 31: ...ation of the door by means of a push control panel remote control 33 4 A 2 Operation of the door in dead man control 35 4 A 3 Use of the emergency manual operator 36 5 SAFETY 37 6 MALFUNCTIONS 38 7 DE...

Page 32: ...of the door and should be kept in the immediate vicinity of the door Instruct users on how to operate the NovoFold high speed stacking door Do not allow third parties to operate the door Before opera...

Page 33: ...trial premises The operation of the door is always motorized and a system is installed to switch to manual mode in the event of a breakdown or failure of the motor The following picture shows the main...

Page 34: ...case the number of work cycles per year is higher than that indicated in the table above more exhaustive maintenance than initially recommended should be carried out In this case contact the manufactu...

Page 35: ...by means of a push control panel remote control This door is installed in places where a high opening speed is required up to 1m s therefore its operation must always be motorized Figure 3 Exterior c...

Page 36: ...After this time the door will close if the safety elements allow it During the closing movement if the control panel remote control or any safety element photocell safety edge etc is pressed the door...

Page 37: ...ry moment a safety element is activated photocell safety edge etc the door will not close until that safety element is released 4 A 2 Operation of the door in dead man control The dead man mode or man...

Page 38: ...asing the crank If this is not done the door will close abruptly ATTENTION Under no circumstances should the door be unlocked without first disconnecting the power supply Figure 15 Detail of the crank...

Page 39: ...t has a detection distance of 12 m ideal for areas where there is a lot of dust or weather conditions that may influence the detection distance And there are other optional systems to minimize the ris...

Page 40: ...lution The door does not open close You have not connected the power supply Connect the power supply Error Check the error code on the control display See if it is possible to solve it if not contact...

Page 41: ...2014 35 EU Electromagnetic Compatibility EMC Directive 2014 30 EU The following harmonised norm has been applied EN13241 Industrial Doors Product Norm Compliance has been checked by the following noti...

Page 42: ...1 Condition of door panel 2 Attachment to door roller 3 Attachment to bottom beam 4 Welds in door panel 5 Securing balls 6 Reinforcement profiles Bottom beam approved 7 Guides 8 Bottom seal 9 Break Aw...

Page 43: ...y Date Name of engineer Signature of engineer Declaration from engineer and or installation firm Company stamp Control approved 25 Push buttons on the box 26 Stop switch 27 General cabling Operation a...

Page 44: ...Manuel d utilisation NovoFold Fran ais TABLEAU DES R VISIONS Revisions table N Date Pr par par R vis par Approuv par Observations 01 02 02 2017 A R P H A L I L T 04 05 08 2019 H A L H A L I L T...

Page 45: ...t de la porte avec les boutons poussoirs t l commande 47 4 A 2 Fonctionnement de la porte en mode homme mort 49 4 A 3 Utilisation de la commande manuelle d urgence 50 5 S CURIT 51 6 DYSFONCTIONNEMENTS...

Page 46: ...doit tre conserv proximit de celle ci Formez les utilisateurs l utilisation correcte de la porte rapide empilable N autorisez aucun tiers actionner la porte Avant la premi re mise en service de la por...

Page 47: ...iels Le fonctionnement de la porte est toujours motoris et requiert l installation d un syst me permettant le passage en mode manuel en cas de panne ou de dysfonctionnement du moteur L illustration su...

Page 48: ...t t que celle initialement recommand e Dans un tel cas veuillez contacter le fabricant afin d estimer la maintenance la mieux adapt e ces conditions d utilisation 3 B Avertissements Surveillez le mouv...

Page 49: ...de Cette porte est destin e tre install e dans des endroits n cessitant une vitesse d ouverture lev e jusqu 1 m s C est pourquoi son fonctionnement doit toujours tre motoris Illustration 3 Station de...

Page 50: ...urit le permettent Lors du mouvement de fermeture si vous appuyez sur les boutons poussoirs la t l commande ou si vous activez un dispositif de s curit quel qu il soit cellule photo lectrique bande de...

Page 51: ...hoto lectrique bande de s curit inf rieure etc la porte ne se fermera pas avant que celui ci ne soit d sactiv 4 A 2 Fonctionnement de la porte en mode homme mort Le fonctionnement du mode homme mort o...

Page 52: ...manivelle Dans le cas contraire la porte se refermera brusquement ATTENTION ne jamais d verrouiller la porte sans avoir pr alablement d branch l alimentation lectrique Illustration 15 Sch ma d taill d...

Page 53: ...n 250 mm du sol Il offre une distance de d tection de 12 m id ale pour les zones tr s poussi reuses ou pour les conditions climatiques susceptibles d alt rer la distance de d tection Il existe d autre...

Page 54: ...l alimentation Branchez l alimentation Erreur Consultez le code d erreur sur l cran de contr le V rifiez si vous pouvez r soudre l erreur Dans le cas contraire contactez le service technique Obstacle...

Page 55: ...nsion des mat riels lectriques 2014 35 EU la directive de compatibilit lectromagn tique CEM 2014 30 EU La norme harmonis e suivante a t appliqu e EN13241 Portes industrielles Norme de produit La confo...

Page 56: ...e approuv e 1 tat du tablier de la porte 2 Fixation rouleau de porte 3 Fixation poutre inf rieure 4 Soudures dans le tablier de porte 5 Billes 6 Profils de renfort Poutre inf rieure approuv e 7 Guides...

Page 57: ...ature du monteur D claration de l installateur et ou de la soci t charg e de l installation Cachet de la soci t Commandes approuv 25 Boutons poussoirs sur le bo tier 26 Interrupteur d arr t 27 C blage...

Page 58: ...Manual de uso NovoFold Espanol N Fecha Realizado Revisado Aprobado Observaciones 01 02 02 2017 A R P H A L I L T 04 05 08 2019 H A L H A L I L T CUADRO DE REVISIONES revisions table...

Page 59: ...Funcionamiento de la puerta mediante botonera telemando 61 4 A 2 Funcionamiento de la puerta modo hombre presente 63 4 A 3 Uso del operador manual de emergencia 64 5 SEGURIDAD 65 6 DISFUNCIONES 66 7 D...

Page 60: ...a y se debe mantener en las inmediaciones de la puerta Instruya a los usuarios sobre c mo accionar la puerta r pida apilable No permita a terceros que accionen la puerta Antes de poner en funcionamien...

Page 61: ...funcionamiento de la puerta siempre es moto rizado instal ndose un sistema para pasar a modo manual en caso de aver a o fallo del motor En la siguiente imagen se muestran los principales componentes d...

Page 62: ...anterior se debe realizar un mantenimiento m s exhaustivo de lo recomendado inicialmente En este caso ponerse en contacto con el fabricante para estimar el mantenimiento m s adecuado para estas condi...

Page 63: ...ta mediante botonera telemando Esta puerta se instala en lugares donde se requiere una elevada velocidad de apertura hasta 1m s por lo que su funcionamiento deber ser siempre motorizado Figura 3 Boton...

Page 64: ...rrar siempre que lo permiten los elementos de seguridad Durante el movimiento de cierre si se pulsa la botonera el telemando o se activa cualquier elemento de seguridad fotoc lula banda inferior de se...

Page 65: ...banda inferior de seguridad la puerta no cerrar hasta que se libere dicho elemento de seguridad 4 A 2 Funcionamiento de la puerta modo hombre presente El funcionamiento del modo hombre presente o cont...

Page 66: ...la manivela Si esto no se realiza as la puerta se cerrar a bruscamente ATENCI N En ning n caso desbloquear la puerta sin haber de sconectado previamente la corriente el ctrica Figura 15 Detalle del s...

Page 67: ...ne una distancia de detecci n de 12 m ideal para zonas en las que exista mucho polvo o condiciones clim ticas que puedan influir en la distancia de detecci n Y existiendo otros sistemas opcionales par...

Page 68: ...sa Soluci n La puerta no se Abre Cierra No ha conectado el suministro de cor riente Conecte el suministro de corriente Error Consultar c digo error en la pantalla del control Mirar si es posible soluc...

Page 69: ...5 EU Electromagnetic Compatibility EMC Directive 2014 30 EU The following harmonised norm has been applied EN13241 Industrial Doors Product Norm Compliance has been checked by the following notified b...

Page 70: ...e la puerta 2 Accesorio a rodillo de puerta 3 Accesorio a la viga inferior 4 Soldaduras en panel de la puerta 5 Fijaci n de las bolas 6 Perfiles de refuerzo Viga inferior aprobado 7 Gu as 8 Junta infe...

Page 71: ...cnico Declaraci n del t cnico y o empresa instaladora Sello de la empresa Control aprobado 25 Pulsadores de la caja 26 Interruptor de parada 27 Cableado general Operaci n aprobado 28 Pulsadores 29 In...

Page 72: ...El proveedor se reserva el derecho de modificar componentes en cualquier momento sin notificaci n previa o directa al cliente Tambi n el contenido de esta publicaci n puede modificarse sin aviso previ...

Page 73: ......

Page 74: ...NL2600815 GHL_NovoFold_TG1 102020 V02 NOVOFERM NEDERLAND B V Tel 31 0 418 654 700 E Mail industrie novoferm nl www novoferm nl...

Reviews: