Label sensor adjustments
Mechanical via thumb wheel with position indicator, electronical setting via display function
Material unwind
Dancer arm for smooth unwinding of labelling material, label reel unwind with integrated friction
brake
Material rewind
Stepper-motor driven rewind mandrel
Ambient conditions
Installation location
• Inside buildings
• Protected from wind and spray water
• Dry
• Not in areas with potentially explosive atmosphere
Operating temperature
• ALX 924/925: +5 bis +35°C
• ALX 926: +5 bis +30°C
Storage temperature
-20 to 70°C
Air humidity
45 to 75% (non-condensing)
Protection class
IP 21
Noise emissions
< 70dB(A)
Sea level
Operation to max. 2000 m above sea level
Interfaces
Interface
Details
RS-232
Baud rate: 1200-115200, 8 bits; suitable connection cable: 1:1 Sub-
D9 extension cable (plug/socket)
RS-232/422/485
Optional (I/O board
1
): Sub-D15, baud rate: 1200-115200, 8 bits
Ethernet
10/100 Base T with TCP/IP, LPD, RawIP printing, DHCP, HTTPD,
FTPD, SNMP
USB (V1.1)
2x USB-A host port, 1x USB-B device port, transfer rate 12 Mb/s.
Signal Interface USI
Optional (USI board
2
): General control signals, signal voltage: 24 V
[Tab. 13] Data interfaces on the ALX 92x.