Service manual
XLP 504 / XLP 506
05/2018 | 09
134
Start cur. len.
(Start current length)
Only visible in service mode
Only if
Options > Selection > Periph. device
= „Dispenser“ oder „Intern. rewinder“
Duration of the start-up current superelevation. To be set is the feed length, during which the in-
creased current is supposed to flow.
Pullback current
Only visible in service mode
Only if
Options > Selection > Periph. device
= „Dispenser“ oder „Intern. rewinder“
After a label was dispensed, the label web has to be pulled back under the print head. To
reach this, the rewinder is rotated slightly in the opposite direction. The braking torque of the
rewinder against this rotation may not be too strong, otherwise this could decrease the impression
accuracy. Because of the brake torque depending on the diameter of the wound up label web, it
has to be corrected at the beginning (min. diameter) and at the end (max. diameter) of the winding-
up process. This is done by the
Pullback current
(supports the backwards rotation in case of low dia-
meter) and the
Break current
(amplifies the brake torque in case of high diameter). Additionally can
be set: The diameter up to which the Pullback current is throttled down to zero (parameter
Back dia-
meter
), and the diameter, from which on the brake current starts (parameter
Break diameter
).
The parameter
Pullback current
sets the support current for the rewinder at the minimum diameter of
25 mm. When the diameter of the rewound label web reaches the set value (
Back diameter
), the sup-
port current will be throttled down to a mimimum.
Back diameter
(Pullback current diameter)
Only visible in service mode
Only if
Options > Selection > Periph. device
= „Dispenser“ oder „Intern. rewinder“
Setting the Pullback current diameter.
If the label web is loose, while it is fed back under the print head, decrease this value in small
steps.
If the material is tightened too much, increase the value in small steps
Break current
Only visible in service mode
Setting range
Default setting
Step width
Easy Plug
[10...40] mm
30 mm
1 mm
#PC2507
Setting range
Default setting
Step width
Easy Plug
--
--
--
#PC2508
Setting range
Default setting
Step width
Easy Plug
[0...120] mm
50 mm
1 mm
#PC2509
Setting range
Default setting
Step width
Easy Plug
[0...100]
0
1
#PC2510