C.4 Adding or Editing Monitor Configurations
Clicking the
Advanced
button also displays an additional section on this page called
Health Monitor
Configuration
. Monitors are an important part of the automatic failover feature, and are separate
processes that perform a specialized task to analyze the health of a specific cluster or all clusters in
the BCC. These monitors report an indication of health to BCC. BCC in turn uses the reported
information to analyze the failover policy to determine if resources should be migrated from a
specific cluster. Business Continuity Clustering 1.1 ships with two monitors (nodecnt and node pnt)
that report an indication of health that represents either the percentage or number of nodes that are
not a member of a specific cluster.
If they are configured by using the Cluster Membership Monitoring Settings table, the fields under
Health Monitor Configuration
should already contain information for the health monitor (nodepnt
or nodecnt) included with Business Continuity Clustering 1.1. Although default values have already
been set, you can customize some of the monitor settings for the cluster membership monitors. If
you have created your own custom monitor, you can click
New
to add configuration settings to your
monitor.
1
In iManager, under
Monitor Name
in the
Health Monitor Configuration
section, select a
monitor and click
Edit
.
2
Under
Clusters
, select the cluster or clusters that you want this monitor to apply to.
3
Specify the maximum health indication that the monitor will report.
This value is used when creating a failover policy to validate the rules. This is the maximum
value that can be used for the threshold type when you create a failover policy. For example, if
you specified percent fail membership monitoring, the maximum values would be 100 (for 100
percent) for the nodepnt monitor. If you specified nodes fail membership monitoring, the
maximum value for the nodecnt monitor is the maximum number of nodes permitted in a
cluster, which is 32. If you created your own custom monitor, the values could be different.
For the nodepnt and nodecnt monitors, the
Maximum Health Indication
value is for information
only, and should not be changed.
4
Under
Short Polling Interval
, specify the number of seconds the monitor will wait each time it
contacts the cluster or clusters to get health information.
The
Long Polling Interval
is not used with the default nodepnt and nodecnt monitors. This
value might be used for some custom monitors.
5
Specify NetWare
®
as the platform that you want to be monitored by the health monitor and
whether you want the monitor enabled for the selected clusters.
The
Optional Parameter
field specifies a monitor-specific string value that is passed to the
monitor as a startup parameter.
The nodepnt and nodecnt monitors do not support optional parameters.
6
Click
Apply
to save your settings.
NOTE:
See the
BCC NDK documentation (http://developer.novell.com/documentation/cluster/
index.html?page=/documentation/cluster/ncss_enu/data/bktitle.html)
for more information on
creating custom failover policies.
Summary of Contents for BUSINESS CONTINUITY CLUSTERING 1.1 SP2 - ADMINISTRATION
Page 4: ...4 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Page 10: ...10 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Page 26: ...26 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Page 36: ...36 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Page 54: ...54 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Page 82: ...82 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Page 92: ...92 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Page 122: ...122 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Page 126: ...126 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...