Chapter 6 Troubleshooting
SMART2 Installation and Operation Manual 1
46
receiver error word and status word.
Table 10: Resolving a Receiver Error Word
11: Resolving an Error in the Receiver Status Word
on the next page and
an Error in the AUX1 Status Word
on page 48 have actions to take when your receiver has an
error flag in these words. If you are not able to resolve the condition, contact
Bit Set
Action to Resolve
0-2
Issue a
FRESET
command (for bit 1, reload new firmware).
4
Contact
5
Check the
VERSION
log. The VERSION log will indicate "Invalid authcode". Upgrade the
auth-code as described in
6
Issue a
FRESET
command
7
See
8
Reserved
9
Check the temperature ranges in:
l
SMART2 Environmental and Electrical Specifications
The operating temperatures are ambient air temperatures. The temperature
sensors on the receiver PCB will reflect higher operating temperatures
(refer to the
HWMONITOR
log). The PCB temperature sensors will trigger a
receiver warning and receiver error at 100°C and 110°C respectively. The
warning and error conditions are captured using the
RXSTATUS
log.
10
Possible hardware or environmental condition. If you cannot resolve the problem,
contact
11
Possible hardware or environmental condition. If you cannot resolve the problem,
contact
Also, check the Auxiliary 2 Status word to determine which PLL is in error.
12-14
Reserved
15
Issue a
FRESET
command and power cycle the unit. If the bit is still present, contact
16
Monitor CPU idle time. Reduce number of logs or the rate of data logging.
17
Ensure that the Version log is consistent with the hardware.
18-19
Reserved
20
SoftLoad is in progress. See
Updating Using SoftLoad Commands
Table 10: Resolving a Receiver Error Word