background image

2

INSTALLING THE ANTENNA

After a site has been selected, install the antenna as follows.

1. Verify that the thread on the mount does not extend more than 7/8" (22 mm) to ensure the plastic 

inside the antenna receptacle is not damaged when the mount is inserted. If it extends further than 7/8" 
(22 mm), add two jam nuts to shorten the exposed thread, ensuring the nuts are well-tightened.

2. Align the mount thread with the metal adapter on the bottom of the antenna and rotate the antenna 

clockwise until it is securely screwed to the mount. Using a wrench, tighten the adapter to the mount. 

3. Remove the dust cap from the antenna’s connector.
4. Attach the male connector of the coaxial cable to the antenna’s TNC connector. 

5. Attach the other end of the coaxial cable to the antenna input port of the receiving device.

The receiving device must provide power as detailed in the 

SPECIFICATIONS

 section of this guide. All 

NovAtel GNSS receivers provide the necessary power through their antenna RF connectors.

ANTENNA CARE

The GPS-702-GG-HV and variants are designed to withstand the elements, including rain, snow and dust. 
However, to ensure your antenna performs optimally, keep the radome (the top surface of the antenna) 
clean and brush off any ice and snow. In addition, ensure the connector remains clean and dry and replace 
the dust cap when a cable is not connected.

The metal adapter on the bottom of the antenna is fixed in place. Do not attempt to remove it.

5/8  x 11 

thread

"

 3/8  - 7/8 9 - 22 mm

"

"  (

)

Mount

Metal 

adapter

Jam nuts 

or flange

Coaxial

cable

TNC connector (N-Type 

connector for GPS-703-GGG-N)

TNC connector

Summary of Contents for GPS-702-GG-HV

Page 1: ...th a 5 8 x 11 thread that extends between 3 8 and 7 8 9 mm and 22 mm A 1 open end wrench Coaxial cable with a male TNC connector A device with an antenna input port that both receives the RF signal and provides 4 5 18 0 VDC to the antenna All NovAtel GNSS receivers provide the necessary power through their antenna RF connectors SITE SELECTION GUIDELINES Before installing the antenna select a site ...

Page 2: ...s TNC connector 5 Attach the other end of the coaxial cable to the antenna input port of the receiving device The receiving device must provide power as detailed in the SPECIFICATIONS section of this guide All NovAtel GNSS receivers provide the necessary power through their antenna RF connectors ANTENNA CARE The GPS 702 GG HV and variants are designed to withstand the elements including rain snow ...

Page 3: ...3 ELEVATION GAIN PATTERN ...

Page 4: ...al impedance 50 VSWR 2 0 1 POWER Input voltage 4 5 to 18 VDC Current typical 35 mA PHYSICAL Diameter 185 mm 7 28 Weight 500 g ENVIRONMENTAL Maximum altitude 9000 m 29 527 5 ft Operating temperature 40 C to 85 C 40 F to 185 F Storage temperature 55 C to 85 C 67 F to 185 F Vibration Random MIL STD 810G 514 6E 1 Category 24 MIL STD 810G 514 6C 3 Category 4 Sine ISO 9022 3 Method 36 10 500 Hz 5 g ASAE...

Page 5: ... Plane ARP TOP VIEW BOTTOM VIEW 100 60 6 69 1 Ø185 Ø170 194 5 SIDE VIEW Height All dimensions are in millimeters mm where 1 inch 25 4 mm PHASE CENTER Tape measure station H W Rev 1 00 P N 0101xxxx MADE IN CANADA www novatel ca NVH99999999 GPS 70x ANTENNA ARP 100 mm 40 mm ARP 4 5 1 8 V D C 5 0 m A m a x 65 mm ...

Page 6: ...e center of the GPS 702 GG HV version comparable by design Only integer hardware revisions affect the phase center offsets For example the numbers given for hardware revision 2 02 are applicable to an antenna labeled H W Rev 2 00 2 04 2 12 and so on Absolute GEO Relative NGS IGS L1 66 mm 2 60 83 mm 3 27 L2 63 mm 2 48 77 mm 3 03 Avg 65 mm 2 56 N A H W Rev 1 00 P N 0101xxxx MADE IN CANADA www novate...

Page 7: ...r without prior written consent from NovAtel In addition the foregoing warranties shall not apply to products designated by NovAtel as beta site test samples experimental developmental preproduction sample incomplete or out of specification products or to returned products if the original identification marks have been removed or altered The warranties and remedies are exclusive and all other warr...

Page 8: ...ergy WEEE products may be recognized by their wheeled bin label 1 ROHS NOTICE The GPS 702 GG HV GPS 702 GG HV DT U and GPS 702 GG HV OD U are compliant with the European Union EU Restriction of Hazardous Substances RoHS Directive 2011 65 EU PATENT NOTICE The GPS 702 GG HV GPS 702 GG HV DT U and GPS 702 GG HV OD U are manufactured and protected under U S Patents 6 445 354 B1 6 452 560 B2 and 7 250 ...

Reviews: