Summary of Contents for Hydrawise HCC-800-M

Page 1: ......

Page 2: ...ower HCC Power Module Wiring Diagram HCC Valve Wiring HCC Installing ICM Station Modules HCC Wire Distance to Valves HCC Installing Wi Fi Antenna Extension Kit Can Two Zones Run Simultaneously with a HCC controller HCC Configure Controller Offline Copyright 2021 Hunter Industries All Rights Reserved 2 ...

Page 3: ...can operate with either 120VAC or 230VAC power Supply wires must be 14AWG 2 mm2 or larger IMPORTANT If you are using the plug in method the wiring is exactly the same but you will require an outlet The plug referred to as a Pigtail three wires including neutral hot and ground can be purchased at most hardware outlets or a Hunter Authorized Dealer 1 P N PIGTAIL Copyright 2021 Hunter Industries All ...

Page 4: ... 1 Turn AC power off at the source and verify that it is off 2 Disconnect the facepack ribbon cable 3 Remove the facepack 4 Remove the cover from the junction box Copyright 2021 Hunter Industries All Rights Reserved 4 ...

Page 5: ...lead from the transformer 4 Connect the incoming white wire NEUTRAL with the blue lead from the transformer 5 Connect the incoming green wire GROUND with the green and yellow wire from the transformer 6 Cap the unused brown wire coming from the transformer Replace the cover of the junction box and screw it into place 7 Replace cover turn on the power and test Copyright 2021 Hunter Industries All R...

Page 6: ...o achieve 10Ω or less resistance at a minimum 8 2 5 m away from the controller HCC Power Module Wiring Diagram Power Module Terminals 1 Green Ground 2 Yellow 24 VAC Transformer 3 Yellow 24 VAC Transformer 4 White Sensor Common 5 Red Rain Sensor 6 Black Flow Meter 7 C Common 8 P MV Pump or Master Valve 9 REM Remote Control Input 10 White Sensor Common 8 Red Rain Sensor 9 Black Flow Meter Copyright ...

Page 7: ...he terminal strip area 4 Route valve wires through the conduit and attach conduit to the controller at the large conduit opening on the right side of the bottom of the cabinet The conduit opening has a triple knockout to accommodate 1 1 or 1 25 32 or 40 mm conduit Each section can be easily removed using a knife 5 Strip 13 mm of insulation from ends of all wires Secure valve common wire to C Commo...

Page 8: ...2 station sizes ICM 400 ICM 800 ICM 2200 These may be added at any time after initial installation Note The ICM 2200 22 Station module must always be installed in the last two module slots to make it compatible Model Max Station Count Total ICM 800 Modules Total ICM 2200 Modules HCC 800 PL 38 Qty 2 ICM 800 Qty 1 ICM 2200 HCC 800 M 54 Qty 4 ICM 800 Qty 1 ICM 2200 HCC 800 SS 54 Qty 4 ICM 800 Qty 1 I...

Page 9: ...tion Tip the two tabs on one end of the module into the mating holes in one end of the slot and tip the module firmly into place STEP 4 STEP 5 STEP 6 Flip the locking lever into the horizontal locked position Press the Reset button on the back of the controller control panel This is required for the controller to recognize the new module Connect field and common wiring as needed and test HCC Wire ...

Page 10: ...ance in feet between controller and valve heavy duty solenoid 24 VAC 350 mA inrush current 190 mA holding current 60 Hz 370 mA inrush current 210 mA holding current 50 Hz Valve Wire Sizing Metric Ground Control Wire 0 5 1 1 5 2 5 4 6 0 5 140 190 210 235 250 260 1 0 190 290 335 415 465 495 1 5 208 335 397 515 595 647 2 5 235 415 515 730 900 1030 4 0 250 465 595 900 1175 1405 6 0 260 495 647 1030 14...

Page 11: ...FI EXT KIT Parts Included Controller Models Cable 3 5 Used only for ACC2 2 model controllers Disregard this cable when using the HCC model Cable 9 Used for HCC 3 and ACC2 2 model controllers SMA Adapter red cap Used only for HCC 3 model controllers Conduit Mounting Hardware Used for HCC 3 and ACC2 2 model controllers Please visit an authorized Hunter distributor near you using our interactive Dist...

Page 12: ...ng conduit knockouts Step 5 Route antenna cable from enclosure through 20 mm plastic electrical conduit Use standard fittings to position the antenna where required Do not exceed supplied cable length Step 6 Route cable and antenna through standard 20 mm threaded adapter with male threaded end up Step 7 Insert the antenna into the open side of the lower tube fit the cable through the slot Adjust h...

Page 13: ...wever it could become an issue if the flow of your irrigation system cannot support operating multiple stations at the same time If you do not have the available water to operate multiple stations at one time you will need to consider and calculate when each program will finish or review the total watering time for each program NOTE Start times do not have to be programmed for the same time If one...

Page 14: ...AM Run Times 10 Minutes each zone Program Name B Watering Days Everyday Start Time 4 05 AM Run Times 10 Minutes each zone Controller Screen Example After 4 05 AM Copyright 2021 Hunter Industries All Rights Reserved 14 ...

Page 15: ...LVE Then touch OK You can now enter the run length you want for your default zone run time Then touch OK Next set how often each zone will run As advised on the previous screen you can set individual frequencies for each zone Touch OK to proceed From ZONES screen you can manually configure each zone according to your desired schedule Touch the ADD button to add a program start time and follow the ...