background image

~ 2 ~ 

NOVATEK-ELECTRO                                                                            

RN-122

 

 

ATTENTION!

 ALL REQUIREMENTS OF THIS OPERATION MANUAL ARE COMPULSORY TO BE MET! 

 

WARNING!

  THE  DEVICE  PLUG  WITH  SOCKET  AND  INTERNAL  COMPONENTS  ARE  UNDER 

POTENTIALLY LETHAL VOLTAGE. 
TO ENSURE THE DEVICE SAFE OPERATION IT 

IS STRICTLY FORBIDDEN THE FOLLOWING: 

 

– TO OPEN AND REPAIR THE DEVICE WITHOUT ANY PROFESSIONAL HELP; 
 
– TO OPERATE THE DEVICE WITH MECHANICAL DAMAGES OF THE HOUSING. 
 
IT IS NOT ALLOWED WATER PENETRATION ON THE INTERNAL ELEMENTS OF THE DEVICE, SOCKET 

AND PLUG. 
 

ATTENTION! 

1) THE DEVICE IS NOT INTENDED FOR THE LOAD COMMUTATION IN CASE OF SHORT CIRCUIT. 

THEREFORE THE DEVICE SHOULD BE OPERATED IN THE ELECTRICAL MAINS PROTECTED BY THE 
CIRCUIT BREAKER WITH INTERRUPTING CURRENT OF 16 A MAXIMUM. 

2) DO NOT CONNECT THE DEVICE TO THE POWER LOAD MORE THAN 3.6 kW. 
3) LOAD CURRENT VALUE SHOULD NOT EXCEED CURRENT VALUE OF THE SOCKET TO WHICH RN-

122 IS CONNECTED. 

 
To improve performance, it is recommended to use the device at load currents not exceeding 10 A. 
 
During operation and maintenance the regulatory document requirements must be met, namely: 
 
Regulations for Operation of Consumer Electrical Installations; 
Safety Rules for Operation of Consumer Electrical Installations; 
Occupational Safety in Operation of Electrical Installations; 

 

Installation,  adjustment  and  maintenance  of  the  device  must  be  performed  by  the  users  having  studied  this 

Operating Manual. 

 
The device is safe for use under keeping of the operating rules. 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Volt Control RN-122

Page 1: ...nd production complies with the requirements of ISO 9001 2015 Dear Customer NOVATEK ELECTRO Ltd Company thanks you for purchasing our products You will be able to use properly the device after careful...

Page 2: ...IN THE ELECTRICAL MAINS PROTECTED BY THE CIRCUIT BREAKER WITH INTERRUPTING CURRENT OF 16 A MAXIMUM 2 DO NOT CONNECT THE DEVICE TO THE POWER LOAD MORE THAN 3 6 kW 3 LOAD CURRENT VALUE SHOULD NOT EXCEED...

Page 3: ...signed to protect household appliances equipment up to 3 6 kW refrigerators air conditioners washing machines TV and audio equipment etc against unacceptable mains voltage fluctuations and the consequ...

Page 4: ...g less than 120 V s 0 12 Fixed time of response in case of voltage spike of more than 450 V when pulse duration reaching more than 1 ms max s 0 02 Accuracy of determination of the voltage operation th...

Page 5: ...this case there is no voltage in the device socket the ON LED is off After restoring the mains voltage parameters the display will show the mains voltage value the voltage will appear in the RN 122 s...

Page 6: ...ll show the value of the mains voltage 3 2 RN 122 operation Normal operation of the device the mains voltage is within the set thresholds the AR time has finished the protected equipment is connected...

Page 7: ...e housing rises above 85 the code will appear on the display the ON LED will be off and the protected equipment will be off In this case it is necessary unplug the device from the power socket let it...

Page 8: ...E MANUFACTURER HAS THE RIGHT TO REFUSE IN WARRANTY SERVICE 5 4 Warranty service is performed at the place of purchase or by the manufacturer of the device 5 5 Post warranty service of the device is pe...