- 8 - 

RNPP-311M

  

                                                                                                                       

NOVATEK-ELECTRO

 

 

6. WARRANTY AND CLAIMS CONDITIONS 

   6.1 Service life is 10 years. Refer to the manufacturer upon the expire of the service life. 

          6.2 Guaranteed storage life 

– is 3 years.  

6.3 Warranty period is 36 month upon the day of sale. 
The manufacturer shall repair the unit, in the compliance with the operating manual by the user, within 

the warranty period. 

RNPP-311M  is not subject to the warranty service in the following cases: 

- expiry of the warranty period; 
- availability of mechanical damages; 
- traces of moisture attack or in the presence of foreign items inside the unit; 
- attempts to open and repair; 
- damage is caused by electric current or voltage in excess to the permissible values as indicated in the 
Operating manual. 
6.4 Warranty service is provided in the place of purchase 
6.5 Post-warranty service shall be provided by the manufacturer. 
6.6 The manufacturer's warranty does not cover  compensation for  direct or  indirect losses associated 
with the unit transp

ortation to the place of purchase or manufacturer’s plant. 

 

7. ACCEPTANCE CERTIFICATE 

 

Multifunctional  voltage  monitoring  relay  RNPP-311M  was  produced  and  accepted  in  accordance  with 

the requirements of effective technical documentation and was recognized as suitable for operation. 

                             

 

 

NOVATEK ELECTRO INDIA PVT. LTD.
C-30, 1ST FLOOR, PATPARGANJ INDUSTRIAL AREA,
DELHI-110092

EMAIL: [email protected]
Ph No- +91-11-42143253
www.novatek-electro.in

Summary of Contents for RNPP-311M

Page 1: ...ompounds for cleaning spirit gasoline solvents etc NEVER ATTEMPT TO REMOVE AND REPAIR THE UNIT Some of the unit components may be live NEVER ATTEMPT TO OPERATE THE UNIT WITH THE MECHANICAL DAMAG THE H...

Page 2: ...on each phase Using toggle switch Figure 1 point 4 RNPP 311M user may select the type of the power circuit 400V or 415V and the set of optionally performed functions using toggle switches 5 8 shown o...

Page 3: ...r phase imbalance measurement not more 2 Protection class against electric shock II Permissible contamination level II Overvoltage category II Nominal voltage of isolation V 450 Operational voltage ra...

Page 4: ...ith isolated Neutral then the measurement accuracy for the phase imbalance and voltage tripping thresholds increase to 5 To terminals 7 8 it is possible to connect 24V AC DC external power supply sour...

Page 5: ...on one of phases and the external power supply of 24 V is absent then RNPP 311M saves operability when voltage at least 140 V 3 3 Adjustments and settings ATTENTION Not to break or turn the knobs plea...

Page 6: ...put terminals 9 10 11 see Figure 1 and Neutral to terminal 12 If necessary connect external 24V AC DC power supply source to terminals 7 and 8 5 Connect output terminals 1 2 4 5 and 5 6 2 3 to the con...

Page 7: ...ion against the phases distortion is carried out by a switch IMB In case the phase loss detected or the voltage on any of the lines becomes lower than 100V then RNPP 311M will turn OFF the power load...

Page 8: ...pair damage is caused by electric current or voltage in excess to the permissible values as indicated in the Operating manual 6 4 Warranty service is provided in the place of purchase 6 5 Post warrant...

Reviews: