MCTRL660 PRO Independent Controller User Manual
www.novastar.tech
13
Step 2 Choose
Input Settings
>
Color Depth
to enter its submenu, select a color depth, and press the knob to apply
it.
Table 6-1 Input bit depth adjustment
Bit Depth
Description
8bit
The loading capacity of the device will not be reduced.
10bit
The loading capacity of the device will be reduced by half. The bit depth must be set.
12bit
The loading capacity of the device will be reduced by half. The bit depth must be set.
6.1.4 Step 4: Quickly Configure the Screen
Follow the steps below to complete quick screen configuration.
Figure 6-5 Quick configuration
Step 1 On the home screen, press the knob to enter the main menu.
Step 2 Choose
Screen Settings
>
Quick Config
to enter its submenu and set the parameters.
Set
Cabinet Row Qty
and
Cabinet Column Qty
(numbers of cabinet rows and columns to be loaded)
according to the actual situation of the screen.
Set
Port1 Cabinet Qty
(number of cabinets loaded by Ethernet port 1). The device has restrictions on the
number of cabinets loaded by the Ethernet ports. See Note a).
Set
Data Flow (Front View)
of the screen. See Note c), d), and e).
Notes
a). If
n
ports are used to load the
screen, the number of cabinets loaded
by each of the first (
n
–1
) ports must be
the same and the integral multiple of
the number of cabinet rows or
columns, and it must be greater than
or equal to the number of cabinets
loaded by the last port.
Example:
If all the 6 Ethernet ports are used to load the screen, the number of
cabinets loaded by ports 1
–5 must be the same and the integral
multiple of the number of cabinet rows or columns. Therefore, you
need to set only the number of cabinets loaded by port 1 according
to the actual situation. The number of cabinets loaded by port 6 must
be less than or equal to the number of cabinets loaded by port 1.
b). For irregular screens, NovaLCT software must be connected to configure the screen.
c). During data flow settings, you can rotate the knob to select a target data flow pattern.
d). During data flow settings, ensure that the cabinets loaded by each Ethernet port are connected one by one
in the same direction.
e). During data flow settings, ensure that Ethernet port 1 is at the beginning position of the whole physical
connection.