NovaLynx Corporation
110-WS-S10
Page 5
August 2021
4
SPECIFICATIONS
5
SITE SELECTION AND INSTALLATION
Select a level area of bare soil or grass where the spiral stake can be installed. The area must be far
enough away from buildings and vegetation that might affect the wind measurements (when installing
an anemometer) or other weather parameters (when installing a compact weather station).
Connections
Screwless terminals (AWG 22 to 28)
RS232 Input
9600 Baud (default) or selectable from 110 to 115200 Baud
Default: Records only the data between specified start (STX) and end (ETX)
Option: May be programmed to log everything (LOG_ALL=Y)
Data Storage
2 GByte (max) removable SD, MMC or MMC mobile card
File System
FAT16 or FAT32 with 8.3 file names. Sector size 512 Bytes
Default: Log every data sample output by the device/sensor
Option: Select logging interval from 1 to 60 seconds
Green LED: Ready to record data
Red LED: Power on, Writing data to SD card
Audible Indicator
Status alert
Real Time Clock Accuracy
±40 ppm at 25 °C
Clock Battery Backup
CR2032
Power
7 to 30 Vdc, (10mA @ 12Vdc typical)
Temperature Range
Operating: -25 °C to +70 °C | Storage: -40 °C to +70 °C
CE marked - EMC directive 2004/108/EC
FCC/CFR 47: Part 15:2004
Assembled Height
7'-2" (2.18 m)
Construction
Tripod: Galvanized steel, Mast: Aluminum
Tripod Height (unfolded)
32"
Tripod Width (unfolded)
32"
Tripod Weight
7.75 lbs (3.5 kg)
Max mast diameter
Ø1.75" (Ø44 mm)
Leg diameter
Ø1.25" (Ø32 mm)
Mast (2 sections)
Ø1.25" x 3' (Ø32 mm x 0.9 m), Swaged one end
Spiral stake
18" (45 cm), Zinc plated
Ratcheting Tie Down
400 lb (180 kg) capacity
Carrying Case
42" (1 m) Padded nylon case with carrying straps
Overall Weight
12.5 lb (5.7 kg)
Tripod with Carrying Case
S10 Data Logger
Visual Indicators
EMC
Data Sample
Logging Interval