background image

NovaLynx Corporation 
 

 

110-WS-S10 

Page 11 

August 2021 

To retrieve data from the SD card, place the card in the memory card reader. Connect the reader to 
your computer's USB port. Windows should recognize the reader as a USB Drive, which will appear in 
File Explorer (Drive letter may vary): 

 

Double-click on the DATA folder to view data files: 

 

Notice the file name contains the date in YYYYMMDD format. Select the day you want to view and 
double-click to open. Once the file is open you can insert a couple of rows at the top, and add column 
headings into the new file. Save the file to your computer rather than to the card, since you have 
altered it by adding the header. 

To avoid completely filling the memory card (which would cause logging to stop), periodically copy all 
the files you want to keep to your computer, then delete the original files from the card. 

 

6.5

 

Data Analysis 

 

In order to make sense of the data when it has been uploaded to a spreadsheet, first make a record of 
the parameters and units that the sensor is reporting. This information can be found in the sensor 
manual, where the default settings are listed. If the sensor has been re-programmed since leaving 
NovaLynx, these parameters may have been changed, and it may be necessary to retrieve the settings 
from the sensor itself. 

Create a spreadsheet with the appropriate column headings and save it. Each time a log file is 
imported to a spreadsheet, insert some blank rows at the top of the sheet, then copy the headings 
from your saved headings file and paste it into the spreadsheet containing your data. Save the 
modified file to your computer for analysis. 

EXAMPLE: 

 

DATE

TIME NODE  DIR  SPEED  CDIR  CSPEED  TOTAL PRECIP  PRECIP INTENSITY

 GPSLOCATION

 TIME

 VOLT  STATUS  CHECK

DEG MS

DEG

MS

MM

MM

(Sample Data)

Q

180 0.06

133

0.21

0

0

+50.763060:-001.0001.60 2017- 11-02T15:07:27.6

5

4

31

Summary of Contents for 110-WS-S10

Page 1: ...S10 UM 20210827 110 WS S10 User Manual 110 WS S10 Portable Weather Station S 10 Portable Weather Station With 200 91000 Ultrasonic Anemometer Phone 530 823 7185 Email nova novalynx com Website www no...

Page 2: ...items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging Please write the RA on the outside of...

Page 3: ...7 6 QUICK START INSTRUCTIONS 8 6 1 Power Supply 8 6 2 Timekeeping 9 6 3 SD Card 10 6 4 Data Collection and Transfer 10 6 5 Data Analysis 11 7 USB ADAPTER SETUP 13 8 REAL TIME MONITORING 13 8 1 View i...

Page 4: ...it possible for the unit to run for several days before the battery must be recharged For longer operation the included battery charger or an optional solar panel can be connected A USB cable is inclu...

Page 5: ...Log every data sample output by the device sensor Option Select logging interval from 1 to 60 seconds Green LED Ready to record data Red LED Power on Writing data to SD card Audible Indicator Status...

Page 6: ...fits the base of the sensor Place that end upwards 4 Center the tripod over the spiral stake and attach the base of the ratchet to the hook that is on the spiral stake 5 Press the release button just...

Page 7: ...arger is not weather proof so special precautions need to be taken if the AC charger is used i e protect it from rain sprinklers A better solution if charging is needed is to install the NovaLynx 110...

Page 8: ...inal To turn the logger OFF o Press the purge button and wait for the LEDs to turn off data is transferred to the card o Remove the card o Disconnect the red battery plug The logger may operate for se...

Page 9: ...u will synchronize the clock 5 Change the DATE parameter to the current date in this format DD MM YYYY 6 Choose File Save As and enter the file name SETUP TXT then click Save 7 In File Explorer locate...

Page 10: ...uffered data is transferred to the card There will be an audio signal to indicate that the button has been pressed The green LED will automatically switch off to indicate that the unit is no longer en...

Page 11: ...e original files from the card 6 5 Data Analysis In order to make sense of the data when it has been uploaded to a spreadsheet first make a record of the parameters and units that the sensor is report...

Page 12: ...r insert rows at the top of the spreadsheet and paste in the column headings DATE TIME NODE DIR SPEED CDIR CSPEED TOTAL PRECIP PRECIP INTENSITY GPSLOCATION TIME VOLT STATUS CHECK DEG MS DEG MS MM MM S...

Page 13: ...is recognized a COM port is opened If you are uncertain which one it is go to the Device Manager on your machine and look for it under Ports COM LPT In the example shown here COM4 is the virtual port...

Page 14: ...s operating press the purge button to save the buffer contents to the memory card then remove the SD card from the logger b If the logger is powered down remove the SD card then connect power to the l...

Page 15: ...d using WindView software Download here http gillinstruments com main software html 1 Enter a name for the sensor if desired 2 Select the output format default shown 3 Set the COM port 4 Enter the Bau...

Page 16: ...ession however precautions must be taken as the charger is not rated for out door use and must be protected from the weather 10 CLOCK BATTERY REPLACEMENT The S10 Logger has an internal battery to main...

Page 17: ...0 0015 02 Terminal Block Sensor Cable Power GND Supply V GND N A GND N A Switch GND1 Switch input 1 1 2 3 4 5 6 7 8 Switch GND 2 Switch input 2 GND RS232 output 2 RS232 input 2 RS232 output 1 RS232 in...

Page 18: ...he output of the sensor to a rate that is suitable for your application If the sensor is providing too much data and cannot be adjusted to a suitable speed the S10 logger can be programmed to ignore s...

Page 19: ...Unchanged ETX 10 ETX 13 SENTENCE2 N SENTENCE2 N Unchanged STX2 2 STX2 2 Unchanged ETX2 10 ETX2 10 Unchanged LOGSTX N LOGSTX N Unchanged LOGETX Y LOGETX Y Unchanged LOGSTX2 N LOGSTX2 N Unchanged LOGETX...

Page 20: ...NovaLynx Corporation 110 WS S10 Page 20 August 2021 13 SENSOR OPTIONS...

Reviews: