BATTERY CHARGING
A voltmeter is provided to check the battery. For best results recharge the battery after each use, but
certainly before it falls below 11.5 volts, as the life of the battery may be shortened otherwise. In general,
more frequent recharging is recommended.
1.
Remove the memory card from the logger.
2.
Connect the RED lead to the BATTERY.
3.
Connect the AC charger connector to the logger's quick-connect plug.
4.
Connect the AC plug of the charger to a duplex receptacle.
5.
Observe the LED on the charger body.
Red
indicates the battery is being charged,
Green
indicates the
battery is fully charged.
If necessary the charger can be connected while doing a long-term logging session; however, precautions
must be taken as the charger is not rated for out-door use and must be protected from the weather.
10
CLOCK BATTERY REPLACEMENT
The S10 Logger has an internal battery to maintain the time and date when the power to the unit is
switched off. Replace the battery if the clock no longer maintains the correct time when the logger
power is disconnected. The logger requires one CR2032 Lithium 3 volt battery.
1.
Disconnect power to the S10 Logger by unplugging the red terminal wire from the 12V battery.
2.
Carefully lift the logger out of the foam to expose the bottom shell of the logger enclosure.
3.
Remove the two screws that hold the shell together, and lift the bottom shell off.
4.
Slide the old battery out and dispose of properly.
5.
Install the new battery with the positive side uppermost.
6.
Replace the cover and install the screws.
7.
Refer to Section 6.2 (Timekeeping) for instructions on setting the clock time.