background image

2.0

SPECIFICATIONS

Sensors:

Wind Speed:

AC Generator

Wind Direction:

120 ohm Potentiometer

Temperature:

Vapor Capillary

Relative Humidity:

Bonded Helical Coil

Barometer:

Aneroid Cell

Measured Ranges:

Wind Speed:

0-25/25-100 mph

Wind Direction:

Nine Cardinal Points

Temperature:

-40 to +140

E

F

Relative Humidity:

0 to 100 % R.H.

Barometer:

27 to 32 in. Hg
& 914 to 1086 mb

Wind Sensor Cable:

5 conductor, 20 AWG

Cable Length:

50 feet ( 15 m )

Temperature Tube:

6 ft ( length not extendable )

Front Panel Finish:

Dark Mahogany

Power requirements:

1 ea "D" cell battery

Display Size:

12" hi x 16.5" w x 3" d
( 305 x 419 x 76 mm )

Weight / Shipping:

16 lbs / 20 lbs
( 7 kg / 9 kg )

3.0

INSTALLATION

Installation of the weather station is relatively simple.  The wind sensor and temperature
sensor  are  mounted  outdoors  with  the  wind  sensor  placed  onto  a  mast  and  the
temperature sensor clamped onto a wall.  The wind sensor has a mounting collar with
locking screws that allow it to be installed onto a 1" O.D. mast or pipe.  If the sensor is to
be located on the roof of a building, the mast should be located on the upwind side.  For
small structures, the mast should be one and one half times as high as the building upon
which it sits.  If this is not practical such as is the case for extremely tall buildings, then the
mast should be at least thirty feet high above the roof.  The nature of the vane requires that
it be aligned to North.  Alignment marks are provided on the sensor housing.  Refer to the
sensor manual for specific instructions.  Route the wind sensor cable in the most direct

2

Summary of Contents for 100-1950

Page 1: ...NOVALYNX CORPORATION MODEL 100 1950 WEATHER STATION INSTRUCTION MANUAL...

Page 2: ...ive items If packing facilities are not available take the equipment to the nearest Parcel Post UPS or freight service and obtain assistance with the packaging Write the RA on the outside of the box W...

Page 3: ...tric Pressure 1 2 0 SPECIFICATIONS 2 3 0 INSTALLATION 2 4 0 THEORY OF OPERATION 3 4 1 Temperature 3 4 2 Barometric Pressure 4 4 3 Relative Humidity 4 4 4 Wind Speed 4 4 5 Wind Direction 4 5 0 CALIBRAT...

Page 4: ...emometer circuit is self generating while the vane circuit requires an external power supply 1 2 Temperature The other meters are mechanical devices The temperature dial is connected to a remotely loc...

Page 5: ...weather station is relatively simple The wind sensor and temperature sensor are mounted outdoors with the wind sensor placed onto a mast and the temperature sensor clamped onto a wall The wind sensor...

Page 6: ...nds Clamp or tie down the wind sensor cable every two to three feet using either plastic wire ties or other appropriate hardware to suit the installation and the supporting structure Secure the temper...

Page 7: ...d is sensed by anemometer cups that turn as the wind speed increases above the starting threshold of the sensor The cups are coupled to an AC generator that generates an AC signal as the cups rotate T...

Page 8: ...nemometer bearings at least annually and especially in areas that experience constant wind activity 5 2 Wind Direction As the vane rotates in a clockwise direction as viewed from above the sensor the...

Page 9: ...rt or by listening to local weather forecasts Adjust the screw at the rear of the barometer to obtain the same reading Follow the local readings for several days and readjust the meter as required Mak...

Page 10: ...THER STATION PART NO DESCRIPTION QTY 100 2130 COMBINATION WIND SENSOR 1 100 19501 TEMPERATURE DIAL ASSEMBLY 1 92080000 BAROMETRIC PRESSURE DIAL 1 92080200 HUMIDITY DIAL 1 92080300 WIND SPEED METER 1 9...