Drive Frequency 

This setting controls how the speed controls throttle (or forward 
drive) responds to the transmitters trigger input. Drive Frequency is 

the frequency at which the information is being sent from the ESC to 
the motor (how many times per second the motor is being cycled on 

and off to control its speed). Changing the Drive Frequency setting 
can be a valuable tuning asset for different types of motor and track 

conditions. 
 

This setting is measured in kHz. Ten preset selections are available in 

the drop down menu. 

 

Increasing the Drive Frequency setting will require more initial trigger 
movement to obtain a given amount of forward drive. This will make 

the throttle feel smoother. The setting is also useful for light vehicles 
as they will accelerate more controllably under initial drive. 

 

ESC Temp Protection 

The speed control has built-in Thermal Overload Circuitry to protect 
the ESC from damage resulting from excessive temperatures. If the 

ESC starts to overheat, this sophisticated circuitry will turn off the 
electronic motor timing advancement. If the ESC’s temperature 

continues to rise, the circuitry drops the ESC’s power output to 25% 
allowing you to safely maneuver your vehicle off of the track. 

 

There are two settings in the ESC Temperature Protection. Selecting 

"On" (default and highly recommended) enables the Thermal 
Overload Circuitry. Selecting "Off", disables the circuitry.  

 

Note: Damage resulting from the ESC overheating is not covered under the 

products warranty.  

  

DISABLING THIS FEATURE IS NOT RECOMMENDED

 

Independent Drag Brakes 

This feature allows the speed control to have the Drag Brake value 
either linked to the Minimum Brake setting or independently adjusted.
 

There are two settings with Independent Drag Brakes. Selecting "Off" 
(default) will tie the Minimum Brake to the Drag Brake value if Drag 

Brakes are set to a value higher than Minimum Brake. Selecting "On" 
will allow the Drag Brake and Minimum Brake settings to be 

independently adjusted. 

 

Minimum Brake 

Minimum Brake is the amount of brake applied with the first pulse of 
transmitter throttle information. 

 

This setting is measured as a percentage of full brakes. Twelve preset 
selections are available in the drop down menu. Custom values can 

entered in increments of 0.1%* 

 

Increasing the Minimum Brake setting starts the braking at a 
stronger/higher level. This is useful for heavier vehicles, minimizing 

the amount of trigger throw required before effective braking is 
applied. Minimum Brake can also be increased in high traction 

conditions when more braking is needed quicker. 

Summary of Contents for NOVALINK 1.3

Page 1: ...INSTRUCTION MANUAL Version 1 3 9 01 2010...

Page 2: ...Saving a Profile 9 Uploading Updating a Profile 9 Resetting to Default Settings 10 Sharing Profiles 10 Disconnecting Your ESC 10 Downloading Software Updates 10 ESC Firmware Upgrade 11 NovaLink Parame...

Page 3: ...OFILES KINETIC The NovaLink offers expanded adjustability on some of the Kinetic and Kinetic 1S s parameters These profiles can only be adjusted through the NovaLink software Fine tune adjustment for...

Page 4: ...result in excess current draw that may disable the USB port and electrical noise generated by the fan may interfere with communication Water and Electronics Don t Mix Never allow water moisture or ot...

Page 5: ...ers and click Run as Administrator i A black command prompt will pop up during installation 6 Once the black command prompt disappears Plug the NovaLink into the USB 7 Return back to the NovaLink Setu...

Page 6: ...Next to continue with the installation Click Next to begin installation Software Registration After installation you can register your software by clicking Register Now or if you plan to skip registra...

Page 7: ...7 Novak Electronics Inc www teamnovak com INSTRUCTION MANUAL Once the installation is complete click Close to exit the installation wizard...

Page 8: ...ogrammed via the NovaLink These settings are kept in the ESC s non volatile memory and when you connect the ESC to the NovaLink the following values will be uploaded from the ESC non volatile memory T...

Page 9: ...ng a Profile 1 Plug your ESC into the NovaLink NOTE It is important to plug your ESC into the NovaLink carefully by matching the colors of the wire to the labels provided on the NovaLink See Precautio...

Page 10: ...feature to open existing profiles After receiving files from other users you can then upload them onto NovaLink to view the parameters and use them on your own ESC 1 Click the Open Exiting Profile ico...

Page 11: ...rom the NovaLink if attached Note make sure your ESC fan is unplugged 6 Start NovaLink 7 Click the Firmware Updater icon 8 The NovaLink Firmware Updater will now be launched 9 Wait until application i...

Page 12: ...d Point Brake End Point is the percentage of the transmitter trigger s brake throw at which the ESC s brakes will reach 100 braking power This setting is measured as a percentage of the full transmitt...

Page 13: ...e This setting is measured as a percentage of full throttle Ten preset selections are available in the drop down menu Custom values can be entered in increments of 0 1 Raising the Dead Band setting in...

Page 14: ...to 25 allowing you to safely maneuver your vehicle off of the track There are two settings in the ESC Temperature Protection Selecting On default and highly recommended enables the Thermal Overload C...

Page 15: ...ffective drive is applied Minimum Drive may need to be reduced to compensate for low traction conditions Minimum Drive is featured in green in the chart below You can control the Minimum Drive value g...

Page 16: ...ltage Cut Off The Voltage Cut Off setting enables or disables the speed controls Smart Stop Circuitry It also allows adjustment of the voltage cut off point based on the type of batteries used in the...

Page 17: ...electronic motor timing advancement at full throttle This provides even higher top speeds The Boost Mode can by entering any value greater than or equal to 20 in the Timing Level Once a value is enter...

Page 18: ...ll increase the maximum amount of electronic motor timing that is applied to the motor throughout the throttle band Using a higher timing setting will result in more overall motor RPM and more current...

Page 19: ...ink Firmware Updater 2 Plug your ESC into the NovaLink Adaptor 3 Start the NovaLink Firmware Updater from the NovaLink program 4 Make sure your ESC fully updates NovaLink Not Displaying Properly on Wi...

Page 20: ...Every Novak NovaLink PC Interface is thoroughly tested before leaving our facility and is therefore considered operational By the act of connecting operating the NovaLink PC Interface user accepts al...

Reviews: