LAS_500_eng

 

 

page  2   

   

Thank you for purchasing  the  

novacare

 LAS 500 Low Air 

Loss Therapy System, 

 a system for the treatment and 

prevention of pressure ulcers. 

A good decision.  
Your novacare® – Team

 

 

 

 

 

Please read the follow instructions carefully  and observe 
the warning notice before commissioning the system 

 

 

 

 

 

 
Table of contents

 :  

 
1.  The system  / Mode of action / areas of application 

page 

2.  Severity of pressure ulcers   

Page 

3.  Maximum recommended patient weight  

Page 

4.  Indications / Contraindications 

Page 

5.  Controls / functions  

Page 

6.  Setting chart  

Page 

7.  Pre-application system preparation  

Page 

5 / 6 

8.  Lock – Function 

Page 

9.  Backup – Function 

Page 

10.  Static mode  

Page  

11.  Bariatric- / Heavy weight function 

Page  

12.  Care – Function 

Page  

13.  Alarm function 

Page  

14.  Practical Test 

Page 

15.  System operation with one cell extracted  

Page 

16.  CPR – Valve 

Page 

17.  Caution note 

Page 

18.  Safety  

 

Page 

19.  Testing for toxicological harmlessness and Bio-compatibility  

Page 

20.  EMC  

 

Page 

21.  Maintenance / Inspection 

Page 

9 / 10 

22.  Hygiene 

 

Page 

10 

23.  Care, cleaning, disinfection 

Page 

10 

24.  Technical information 

Page 

11 

25.  Waste Disposal 

Page 

11 

26.  Warning notice for private, non-professional operators 

Page 

12 

27.  Information for installation and instruction 

Page 

12 

28.  Warranty 

 

Page 

13 

29.  Scope of Supply 

Page 

13 

30.  Product Identification / Item no.  

Page 

13 

31. 

Notes 

 

Page 

14

 

 

 
 

Summary of Contents for LAS 500

Page 1: ...Operating Instructions LAS 500 Low air Loss System...

Page 2: ...tion Page 5 6 8 Lock Function Page 6 9 Backup Function Page 7 10 Static mode Page 7 11 Bariatric Heavy weight function Page 7 12 Care Function Page 7 13 Alarm function Page 7 14 Practical Test Page 8...

Page 3: ...placement system for clinical stationary and ambulatory care taking The system consists of a control unit with digital operating unit and a mattress system with 18 arranged in a transverse manner 2 Se...

Page 4: ...eight observe chart 2 Setting of alternating pressure interval Cycle 3 Alternating mode 4 Static mode 5 Care Mode 6 Start button Operate or Standby 7 display alternating pressure interval Cycle 5 95 i...

Page 5: ...the bed using the fixation hooks The automatically retractable hooks adjust to the foot end of the bed and provide a secure hold Upon removal of the control unit the hooks automatically retract to the...

Page 6: ...ments 0 95 Min by pushing the button Push the Alter Button to return to 5 12 Set patient weight by pushing the key Use setting chart for support 13 The patient can now be placed onto the mattress 14 N...

Page 7: ...tric mattress optional in combination with this function The mode is activated by pushing the BARIATRIC Button The Bariatric LED lights up 12 Use of CARE Function The LAS 500 control unit features a C...

Page 8: ...d once again without difficulty The extracted cell can in re inserted in the opposite sequence 16 CPR Valve The novacare LAS 500 Low Air Loss Therapy System is equipped with a CPR emergency valve It p...

Page 9: ...with RL 93 42 EWG Use and applications are subject to these legal foundations Systems are suitable for reuse However hygiene directives must be observed and flawless operation must be ensured Mainten...

Page 10: ...cribed by the respective manufacturer Guarantee claims become null and void if inappropriate and unlisted preparations are used or are used inappropriately We recommend our cleaning service Please ref...

Page 11: ...al PU Max Flow 1200 ltr min Cycle Adjustable 5 95 Minutes in 5 Minute intervals Surrounding conditions Temperature Application operation 5 50 Transport storage 10 60 Rel humidity Application operation...

Page 12: ...medical care products They are sold by novacare gmbh primarily to medical experts care taking personnel specialized medical dealers users medical facilities etc and put at the disposal of professional...

Page 13: ...intervals prescribed by the manufacturer are adhered to As far as warranty claims are asserted and if during the subsequent inspection it is found that the damages are of wear and tear or are not subj...

Page 14: ...LAS_500_eng page 14 31 Notes...

Page 15: ...LAS_500_eng page 15...

Page 16: ...acare de Copyright The instruction manual is protected by copyright Any reproduction and duplication recording in online services and the internet as well as any saving or copying on data carriers lik...

Reviews: