24. Technical information: 

• 

Control unit : 

Weight 

6.1 kg 

 

dimensions : 

42  x 27  x 18.5 cm 

 

Length Power cable 

3 m 

 

Spannungswerte : 

AC 220-240 V / 50 Hz 

 

At maximum 

 up to 2.5 VA / 575 W 

 

Fuses : 

TIAH 250 VAC 1A 

 

Protection class : 

Type BF / class 1 

• 

Mattress - Standard : 

dimensions: 

200 x 90 x 24 cm 

 

Weight : 

ca. 13 kg 

• 

Mattress - Bariatric :  

Dimensions: 

200 x 120 x 24 cm 

(Optional) 

Weight : 

ca. 15 kg 

 

Material  

PU –coated 

 

 

 Polyester texture

 

 

 

• 

Cells : 

Dimensions : 

90 x 26 x 22 cm 

 

Material 

 PU 

• 

Max. Flow 

 

< 1200 ltr. / min. 

 

• 

Cycle 

Adjustable 

 5 - 95 Minutes 

 

(in 5-Minute- intervals) 

• 

Surrounding conditions: 

 

Temperature 

Application/operation 

5° ~ 50° 

 

 

Transport / storage 

-10° ~ 60° 

 

 

 

Rel. humidity 

Application/operation 

20 % – 90 % 

 

 

Transport / storage 

20 % – 90 % 

 

 
 
 
 

25. Waste Disposal 

Mattress system 

The  materials  used  for  the  mattress  does  not  pose  any  danger  for  the  environment. 
They may be disposed off with the household waste 
Disposal via official waste incineration is preferred. 

 
Control units 

Control  units  are  considered  electric  equipment  waste.    Please  contact  the  proper 
waste disposal authorities. 

 

Novacare gmbh electric equipment is registered (see symbol) 

WEEE – Reg.- No. DE – 89 403 200 

 
 
 
 

Summary of Contents for LAS 500

Page 1: ...Operating Instructions LAS 500 Low air Loss System...

Page 2: ...tion Page 5 6 8 Lock Function Page 6 9 Backup Function Page 7 10 Static mode Page 7 11 Bariatric Heavy weight function Page 7 12 Care Function Page 7 13 Alarm function Page 7 14 Practical Test Page 8...

Page 3: ...placement system for clinical stationary and ambulatory care taking The system consists of a control unit with digital operating unit and a mattress system with 18 arranged in a transverse manner 2 Se...

Page 4: ...eight observe chart 2 Setting of alternating pressure interval Cycle 3 Alternating mode 4 Static mode 5 Care Mode 6 Start button Operate or Standby 7 display alternating pressure interval Cycle 5 95 i...

Page 5: ...the bed using the fixation hooks The automatically retractable hooks adjust to the foot end of the bed and provide a secure hold Upon removal of the control unit the hooks automatically retract to the...

Page 6: ...ments 0 95 Min by pushing the button Push the Alter Button to return to 5 12 Set patient weight by pushing the key Use setting chart for support 13 The patient can now be placed onto the mattress 14 N...

Page 7: ...tric mattress optional in combination with this function The mode is activated by pushing the BARIATRIC Button The Bariatric LED lights up 12 Use of CARE Function The LAS 500 control unit features a C...

Page 8: ...d once again without difficulty The extracted cell can in re inserted in the opposite sequence 16 CPR Valve The novacare LAS 500 Low Air Loss Therapy System is equipped with a CPR emergency valve It p...

Page 9: ...with RL 93 42 EWG Use and applications are subject to these legal foundations Systems are suitable for reuse However hygiene directives must be observed and flawless operation must be ensured Mainten...

Page 10: ...cribed by the respective manufacturer Guarantee claims become null and void if inappropriate and unlisted preparations are used or are used inappropriately We recommend our cleaning service Please ref...

Page 11: ...al PU Max Flow 1200 ltr min Cycle Adjustable 5 95 Minutes in 5 Minute intervals Surrounding conditions Temperature Application operation 5 50 Transport storage 10 60 Rel humidity Application operation...

Page 12: ...medical care products They are sold by novacare gmbh primarily to medical experts care taking personnel specialized medical dealers users medical facilities etc and put at the disposal of professional...

Page 13: ...intervals prescribed by the manufacturer are adhered to As far as warranty claims are asserted and if during the subsequent inspection it is found that the damages are of wear and tear or are not subj...

Page 14: ...LAS_500_eng page 14 31 Notes...

Page 15: ...LAS_500_eng page 15...

Page 16: ...acare de Copyright The instruction manual is protected by copyright Any reproduction and duplication recording in online services and the internet as well as any saving or copying on data carriers lik...

Reviews: