NFS2-3030/E Installation Manual — P/N 52544:N1 07/18/2014
System Overview
System Components
2.1.2 Options
Refer to Section 2.2 “System Components” for descriptions of the various optional modules.
•
Rubberized keypad with a standard “QWERTY” keyboard layout, a 640-character LCD
display, indicator LEDs, and switches.
•
Separately ordered Loop Control Modules and Loop Expander Modules provide up to ten
SLC loops.
•
Optional equipment includes: ACS devices, UDACT/UDACT-2 Universal Digital Alarm
Communicator/Transmitter, ACM-8R remote relay module to provide additional relay points,
and audio/voice components.
2.1.3 System Limitations
System expansion must take into consideration the following:
1.
The physical limitations of the cabinet configuration.
2.
The electrical limitations of the system power supply.
3.
The capacity of the secondary power source (standby batteries).
2.2 System Components
Central Processing Unit (CPU) and Keypad/Display
The central processing unit for the
NFS2-3030 system can be ordered with a keypad/display (P/N CPU2-3030D) or without a
keypad/display (P/N CPU2-3030ND). CPU2-3030D serves as “primary display” version for ULC
applications. CPU2-3030ND is intended for use in network applications; LEDs and momentary
switches on the printed circuit board mimic those on the keypad to enable operation and trouble-
shooting at the panel when it is used without a local primary display.
Power supply
The main power supply is AMPS-24/AMPS-24E, which pr24 VDC
power and a battery charger for a basic system. Auxiliary power supplies and/or battery chargers
are available to customize large systems.
Enclosures
Four cabinet sizes are available; doors and backboxes are ordered separately. “A”
size backboxes hold one row of modules, “B” size backboxes hold two rows, “C” size backboxes
hold three rows, and “D” size backboxes hold four rows. See Section 2.4 “System Cabinets” for
basic description. A variety of dress panels, trim rings, and blank modules are available to
accompany specific combinations of system equipment; contact Notifier for a complete parts list.
SLC Loops: LCM-320, LEM-320
To provide one SLC loop, connect one LCM-320 to the
panel. Connect an LEM-320 to the LCM-320 to provide a second loop. Up to five pairs of modules
can be installed on the panel to provide a maximum of ten SLC loops.
Network Connection
Connect a wire or fiber version of the NCM or the HS-NCM to provide a
connection to the Noti•Fire•Net (network version 5.0 or higher) or High-Speed Noti•Fire•Net.
!
WARNING: UL 9TH EDITION COMPLIANCE
THIS PRODUCT HAS BEEN CERTIFIED TO COMPLY WITH THE REQUIREMENTS IN THE
STANDARD FOR CONTROL UNITS AND ACCESSORIES FOR FIRE ALARM SYSTEMS, UL 864
9TH EDITION. OPERATION OF THE NFS2-3030/E WITH PRODUCTS NOT TESTED FOR UL 864
9TH EDITION HAS NOT BEEN EVALUATED AND MAY NOT COMPLY WITH NFPA 72 AND/OR
THE LATEST EDITION OF UL 864. THESE APPLICATIONS WILL REQUIRE THE APPROVAL OF
THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ).
THIS MANUAL MENTIONS PRODUCTS THAT HAVE RECEIVED UL 864, 9TH EDITION
CERTIFICATION, AND ALSO MENTIONS PRODUCTS THAT HAVE NOT.
FOR A COMPLETE
LIST OF ALL PERIPHERALS THAT CAN BE USED WITH THIS FIRE ALARM CONTROL PANEL
(FACP), AND WHICH OF THOSE PERIPHERALS HAVE NOT RECEIVED UL 864, 9TH EDITION
CERTIFICATION AND MAY ONLY BE USED IN RETROFIT APPLICATIONS, SEE SECTION 2.5,
“COMPATIBLE EQUIPMENT”, ON PAGE 17.