11
3.3.3.2 Stage 1 & Stage 2 - Graph
The Stage 1/Stage 2 graph displays a visual of the curve the controller will use to progress the nitrous/fuel solenoids. The
Ramp Builder App. will generate a linear curve based on your inputs and display it in graph menu. Using the arrows, you can
select 15 different points and manually slide them up and down to create your own curve.
NOTE: NOS recommends only
advanced users use this feature as improper tuning can result in engine damage.
Displayed in the lower right hand
corner will be the time and Duty Cycle % of the currently selected point use this as a guide to dial in the curve. If a high
degree of accuracy is required simply quickly double tap the Stage 1/Stage 2 text
enu will appear.
When complete, press the
save button. If you made a mistake or do not want to save, press the
back button to exit
the graph without saving.
3.3.3.3 Stage 1 & Stage 2 - Configuration
The configuration menu will allow you to adjust the following settings.
PWM Frequency
This is the frequency at which the solenoids are driven. This is adjustable from 10 to 50
Hz.
NOS recommends a default setting of 20 Hz for most of our solenoids and 15Hz for the
18178NOS & 18178BNOS.
If using another brand of solenoids, check for their recommended frequency.
Ramp/Pause Mode
This allows the controller to either reset or resume the progressive ramp that has
been programmed. In reset mode, the ramp will start over from the beginning when the trigger has been
deactivated and reapplied. In resume mode, once the trigger is deactivated and reapplied, the ramp will
return to the last point that the system was active and continue the ramp from that point.
TPAS Mode
Throttle position activation switch mode. Changes the type of throttle input. Choose from the
following:
WOT to GND Switches when a ground signal is applied, commonly used with a WOT
microswitch.
WOT to 12V Switches when a 12V signal is applied.
TPS to 90% - Used with Throttle Position Sensors.
Disable Turns off the throttle input and only activates the stage based off RPM.
Control Output Type
Changes the output type for the stage. Choose from the following:
Active Low Switch to ground
Active Low (Pull Up) Pulled up to battery (12V), switch to ground
Active High Switch to battery (12V)
Active High (Pull Down) Pulled down to ground, switch to battery (12V)
Push-Pull Battery (12V) when active, ground when inactive
Control Output Delay
The time (in seconds) the controller waits before turning on the control output
NOTE:
This output is useful when using a timing retard, activation switch, or any other switch, which
requires an input.
Exit
without
saving
Time and %
duty cycle of
selected point
Change Selected Point. Selected
Point will be highlighted in RED
Save Graph
Double tap to enter Fine Tune
Menu
Save
Exit without saving
Fine Tuning Menu
Use arrows to change values or
press on the number to enter
the manual entry.
Slide point
up/down to
edit