Remove the motor cable clamp and terminal
box cover using a screw driver.
Insert the cable from the control panel inside
the clamp as illustrated here.
Make sure the terminals are as shown here
(not bar crossing the terminals).
Remove the nuts of each terminal and
connect the proper cable to the proper
terminal (follow labels attached to cables).
Secure each cable with the nuts previously
removed.
Connect the ground wire.