Low Voltage
Control
Wiring
Incoming
Power
Input Power Configurations
CONCEALED WIRING
Thread conduit fitting(s) into backplate as shown. A
second conduit fitting is required for low voltage
control wiring. CHECK LOCAL CODES. Pull conduit
out of header and attach to conduit fittings before
mounting Operator to door frame. Attach incoming
ground wire to backplate with ground screw as
illustrated below.
SURFACE WIRING
An optional bracket is provided for use with surface
wiring. Remove the two cable clamps screws and
slip the bracket under the cable clamps. Push the
cable clamp screw through the bracket holes and
tighten. ½” conduit fittings can now be installed on
the bracket.
Optional Bracket
(for surface wiring)
Ground
Lead
Power
Leads
Ground
Screw
(Green)
Cable
Clamps
Conduit
by Others
(from top)
“T1” Power
Input
Terminal
80-9357-0110-020 Rev. A
5
Ground Wire Connection – Ground wire must be secured to backplate under head of (green) ground screw nearest to “T1” Power Input
Terminal. Screw labeled “GND”.
General Electrical Data
Maximum current draw of unit is 0.6 amps.
Breaker Switch protects the motor assembly and inverter and
has a 5 amp rating.
Maximum wire size is:
12AWG at terminals HOT and COM on “T1” Power Input
Terminal.
14AWG at terminals 1 thru 4 on Accessory Terminal .
18AWG at terminals 22 thru 25 on “T1” Power Input
Terminal.
24
23
22
25
HOT
COM
Terminal
Description
HOT
25
23
24
22
COM
Common power lead
Hot power lead
Circuit Breaker
Switch
Circuit Breaker
Common connection to Circuit Breaker /
Inverter