Norton LEO 5710 Series Installation Instructions Manual Download Page 2

80-9357-0110-020 Rev. A

2

Door Opening

Angle

Dim “A”

Up to 110°

111° to 180°

15-1/2 (394)

13-1/4 (337)

General Templating Information

Fasteners for Frame

• Before beginning the installation, verify that the door frame is

properly reinforced and is well anchored in the wall.

• Concealed electrical conduit and concealed switch or sensor

wires should be pulled to the frame before proceeding.

• Unreinforced hollow metal frames and aluminum frames should

be prepared and fitted with 1/4-20 blind rivet nuts, furnished by
others.

• 1/4-20 Machine screws for hollow metal and aluminum.

• No. 14x2-3/4" (70mm) long sheet metal screws for wood.

Fasteners for Door

• 1/4-20 Machine screws.

• 3/8" diameter x 1-5/8" (41mm) long sex nut.

WARNING:

Make sure that (120V, 60Hz) input power is turned off at facility’s

circuit breaker before proceeding with installation.

main

Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in hollow metal

doors and frames is charted at the left of this page.

• Do not scale drawing.
• Left hand door shown.

• Maximum frame reveal is 6-7/8” (175mm) for this application.

• This template information based upon use of 5" (127mm)

maximum width butt hinges. A separate template will be
supplied for other conditions.

• Conduit hole nearest the hinge is suggested for 120 VAC power

input.

Hollow Metal Door Frame Reinforcing

Frame

Material

12 Ga.

.1046

14 Ga.

.0747

16 Ga.

.0598

18 Ga.

.0478

(2.66)

(1.90)

(1.52)

(1.21)

12 Ga.

.1046

10 Ga.

.1343

10 Ga.

.1343

8 Ga.

.1644

(2.66)

(3.41)

(3.41)

(4.18)

18 Ga.

.0478

12 Ga.

.1046

12 Ga.

.1046

10 Ga.

.1343

(1.21)

(2.66)

(2.66)

(3.41)

Reinforcing

Recommended

Min. Required

Template

1-1/8”

(29)

1-1/4

(32)

1-7/16

(37)

11

(279)

22

(559)

7-9/16

(192)

13-7/16

(341)

1-1/8

(29)

C

Hinge or Pivot

1/4-20 Machine Screws
or No. 14 Wood Screws

(6 Places)

7/8 (23) Dia.

(2 Places)

3/8 Dia.

Sex Nuts

(3 Places)

Frame

Rabbet

Frame
Stop/Soffit

3

(76)

13-13/16

(350)

1/2

(13)

A

11-11/16

(297)

6”

Min.

Clearance

General Templating Information

14-3/16

(360)

12-15/16

(329)

13-13/16

(351)

Summary of Contents for LEO 5710 Series

Page 1: ...ctice in accordance with national and local wiring codes Note Unless otherwise noted all dimensions are given in inches millimeters Minimum suggested and required material thickness for hollow metal f...

Page 2: ...ches mm Thickness recommended for reinforcements in hollow metal doors and frames is charted at the left of this page Do not scale drawing Left hand door shown Maximum frame reveal is 6 7 8 175mm for...

Page 3: ...r unreinforced hollow metal frames or for aluminum frames six 6 Connect conduit to frame side of backplate Fasten unit to door frame seven screws Fasten unit to door frame seven screws Mount conduit b...

Page 4: ...door Allow door to close Loosen and readjust Open Position Ring as necessary to obtain desired door open position Tighten set screw Make all connections necessary for any accessories to the 4 positio...

Page 5: ...talled on the bracket Optional Bracket for surface wiring Ground Lead Power Leads Ground Screw Green Cable Clamps Conduit by Others from top T1 Power Input Terminal 80 9357 0110 020 Rev A 5 Ground Wir...

Page 6: ...lapsed 1 2 3 4 1 2 3 4 Door 1 Door 2 POT FUNCTION DESCRIPTION CL Obstruction Detection on Open CW Increase CCW Decrease MAX Door Open Speed CW Increase CCW Decrease MIN Motor Reversing Speed CW Increa...

Page 7: ...Supplied by Others 24VDC Out 24 VDC Electric Strike Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts Notes 1 Power input to Door Operator Unit is at T1 Power Input Terminal...

Page 8: ...e requirements for the Power Assist Door POR Function is designed to meet or exceed all of the requirements for the Low Energy Power Operated Door C US UL An ASSAABLOY Group Co 1902 Airport Road Monro...

Page 9: ...hinges This template not for use with offset pivots Ceiling clearance of 6 152 mm from frame rabbet is required for this application Maximum frame reveal is 1 8 3 mm for this application Conduit hole...

Page 10: ...11 11 16 297 3 8 19 14 3 16 360 13 13 16 351 Door Opening Angle Dim A Dim B Up to 110 111 to 170 12 305 9 1 2 241 13 1 4 337 15 3 4 400 Frame Rabbet REVEAL Notes Do not scale drawing Left hand door sh...

Page 11: ...cordance with national and local wiring codes Note Unless otherwise noted all dimensions are given in inches millimeters Minimum suggested and required material thickness for hollow metal frames skin...

Page 12: ...mm Thickness recommended for reinforcements in hollow metal doors and frames is charted at the left of this page Do not scale drawing Left hand door shown Maximum frame reveal is 7 178mm for this app...

Page 13: ...ith the flat corner of the pinion shaft square See Fig 1 upper right Frame Door A Prepare holes for 1 4 20 machine screws or No 14 x 2 3 4 70mm wood screws Blind rivet nuts by others are suggested for...

Page 14: ...en door reaches 20 switch Breaker Switch to position cutting power to the unit Allow door to fully close door may be manually pulled closed Once door has fully closed manually open door slightly and i...

Page 15: ...talled on the bracket Optional Bracket for surface wiring Ground Lead Power Leads Ground Screw Green Cable Clamps Conduit by Others from top T1 Power Input Terminal 80 9357 0130 020 Rev A 5 Ground Wir...

Page 16: ...apsed 1 2 3 4 1 2 3 4 Door 1 Door 2 POT FUNCTION DESCRIPTION CL Obstruction Detection on Open CW Increase CCW Decrease MAX Door Open Speed CW Increase CCW Decrease MIN Motor Reversing Speed CW Increas...

Page 17: ...Supplied by Others 24VDC Out 24 VDC Electric Strike Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts View of Jumper in Normally Open Position For Use With Fail Safe Strike...

Page 18: ...e requirements for the Power Assist Door POR Function is designed to meet or exceed all of the requirements for the Low Energy Power Operated Door C US UL An ASSAABLOY Group Co 1902 Airport Road Monro...

Reviews: