CL
MAX
MIN
DEC/B
ACC
COMP
Component Layout
Inverter Details
80-9357-0130-020 Rev. A
6
Standard Function with Switches
1
2
3
4
1
2
3
4
Notes:
1. Power input to Door Operator Unit is at
Power Input Terminal (not shown)
120VAC 60Hz.
Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary
dry contacts
Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary
dry contacts
Operation:
Doors are normally closed.
Activating either switch will open both doors. Door will
close after hold open time delay has elapsed.
1
2
3
4
1
2
3
4
Door 1
Door 2
POT
FUNCTION
DESCRIPTION
CL
Obstruction Detection on Open
CW - Increase
CCW - Decrease
MAX
Door Open Speed
CW - Increase
CCW - Decrease
MIN
Motor Reversing Speed
CW - Increase
CCW - Decrease
DEC/B
Hold Open Time (5 - 30 Seconds)
CW - Increase
CCW - Decrease
ACC
Door Mounting (Factory Set)
Full CW - Push
Full CCW - Pull
COMP
Motor Torque at Hold Open
Position
CW - Increase
CCW - Decrease
Trimpot Adjuster
Inverter Adjustments:
Based on function adjustment desired, use table above to determine
which POT is to be adjusted.
Using Trimpot Adjuster, shown below and supplied with screw pack,
adjust the appropriate POT using illustration on the left.
Note: Trimpot may be
adjusted through slot
in finger guard.