*11 and 12 In option
Electrical Motor and switch (6)
Motor with 7,5kW: Low voltage trigger (NVR) prevents the motor to restart for example after a power
cut.
The electric motor has overload protection. Thermal overload tripping can occur for two reasons:
a. tripping under light load
If connection is incorrect
If a phase is not under load
Check the connections and the phase voltage before restarting the machine.
b. tripping under heavy load
If motor has been overloaded
The ON-OFF switch also serves as emergency stop.