9
11. ALARM AND DIAGNOSTIC MESSAGE
The appliance forecasts the appearance of special
conditions:
-
Irregular operation or damage. In this case in the
various displays are presented code fault.
Follows the list the code and relative conditions of fault.
error1 -
Interruption of Temperature sensor
error2 –
Temperature sensor problem.
error3 –
Micro Switch motor up
.
error4
– Micro Switch motor down.
error5 –
Overheat electronic control
11.1
TURN OFF IN CASE OF DAMAGE
In case of damage disconnect the appliance:
-
Disconnect the automatic switch of electric supply
that is found before the appliance and closed
valves water.
-
Contact with the technical support dealer.
.
.
12.
CLEANING AND MAINTENANCES
-
In the end of each day you must clean the
appliance using the suitable products and
following the directives of supplier.
-
Don't wash the appliance with direct of water
external.
-
Don't use for the cleaning of steel products that
contain chlorine (bleach, hydrochloric acid etc),
even if they are dissolved.
Do not use corrosive substances (for example
muriatic' acid) in order to you clean the flooring
under the appliance.
13. REMOVE OIL
To remove the oil of the tank you can connect the
round metal parts which follow the machine and
push out the handle of the tap.
REMOVE THE OIL WHEN IT IS NOT HOT
BECAUSE CAN BE CAUSE BURNING.