INTERNAL REFERENCE GENERATOR
Function
Syntax (commands must be sent with upper-case)
Comments
REF_GEN<b>FREQ?<cr><lf>
Queries the frequency
setting for the
internal reference
generator.
Reference
Generator
Frequency
REF_GEN<b>FREQ<b><value><cr><lf>
Sets the frequency
setting for the
internal reference
generator. Frequency
range is 47.0 to
20000.0 Hz.
REF_GEN<b>VOLT?<cr><lf> Queries
the
voltage
setting for the
internal reference
generator.
Reference
Generator
Voltage
REF_GEN<b>VOLT<b><value><cr><lf>
Sets the voltage
setting for the
internal reference
generator. Voltage
range is 2.0 to 115.0
volts.
REF_GEN<b>STATE?<cr><lf> Queries
the
output
state of the internal
reference generator.
Query returns:
‘OPEN’, or
‘CLOSED’.
Reference
Generator
Output State
REF_GEN<b>STATE<b><OPEN|CLOSE><cr><lf>
Sets the output state
for the internal
reference generator.
The CLOSE state
will out allow
reference signals to
be available at the
output connectors.
The OPEN state will
prevent the reference
signals from being
outputted.
North Atlantic Industries, Inc.
631.567.1100/631.567.1823 (fax) Revision 2.0.0.2
Reference Guide
110 Wilbur Place, Bohemia, NY 11716
www.naii.com
/ e-mail:[email protected]
Page 24 of 50