![North Atlantic 8810A Programmer'S Reference Manual Download Page 15](http://html.mh-extra.com/html/north-atlantic/8810a/8810a_programmers-reference-manual_1707615015.webp)
Language
Support
API<chan><b>ANG_LIMIT<b>HI?<cr><lf> Queries
the
upper
limit test value
settings for the
channel.
Query returns upper
limit in degrees:
Range: 0.0000 <
value < 359.9999
or
Bipolar Range:
-180.0000 < value <
+180.0000
API<chan><b>ANG_LIMIT<b>HI<b><value><cr><lf>
Sets the upper limit
test value in degrees:
Range: 0.0000 <
value < 359.9999
or
Bipolar Range:
-180.0000 < value <
+180.0000
API<chan><b>ANG_LIMIT LO?<cr><lf>
Queries the lower
limit test value
settings for the
channel.
Query returns lower
limit in degrees:
Range: 0.0000 <
value < 359.9999
or
Bipolar Range:
-180.0000 < value <
+180.0000
API<chan><b>ANG_LIMIT<b>LO<b><value><cr><lf>
Sets the lower limit
test value in degrees:
Range: 0.0000 <
value < 359.9999
or
Bipolar Range:
-180.0000 < value <
+180.0000
North Atlantic Industries, Inc.
631.567.1100/631.567.1823 (fax) Revision 2.0.0.2
Reference Guide
110 Wilbur Place, Bohemia, NY 11716
www.naii.com
/ e-mail:[email protected]
Page 15 of 50
8810A Programmer’s