Troubleshooting Page 177 of 206
Meridian Companion Installation and Maintenance Guide
Config warning
Cards have been
relocated and the
system is disabled.
See “Handling Meridian Companion exceptions”
on page 160.
Config failure
Cards have not been
reinstalled correctly
in their original order
and the system is
disabled.
See “Handling Meridian Companion exceptions”
on page 160.
Config ambiguous
The system cannot
recognize a card.
Avoid empty slots between Meridian Companion
cards. Make sure that every CMBC card has at
least one Base Station connected and powered
on. Correct the problem and press
RESUME
.
System coldstart
A nonrecoverable
NVRAM corruption
was detected during
restart. A cold start
occurs
automatically. This
message appears
only at power up.
This is normal for a new installation. If this occurs
on repowering an existing system, it means that
the system has lost its memory.
Reprogram the system using the programming
record. Reregister all portable telephones.
Re-Eval required
The Meridian
Companion system
has detected a need
for System
Reevaluation.
This message displays for three reasons.
• a new Base Station was added to the system
• a Base Station was moved to a different port
• a Base Station lost power and the TCM port
location changed
Run System Reevaluation immediately or
schedule a System Reevaluation.
Table 41 : Alarm troubleshooting (continued)
Alarm
Meaning
Possible causes and actions
Summary of Contents for Meridian Companion
Page 2: ......
Page 10: ...Page x of x 553 3601 220 Standard 4 00 November 1998...
Page 108: ...Page 98 of 206 Activating wireless communication 553 3601 220 Standard 4 00 November 1998...
Page 128: ...Page 118 of 206 Programming user options 553 3601 220 Standard 4 00 November 1998...
Page 208: ...Page 198 of 206 List of terms 553 3601 220 Standard 4 00 November 1998...
Page 217: ......