To install the BCM50 wall-mount bracket
1
Optional:
Mount a plywood backboard securely to the wall. Use a ruler and a level to level the
plywood backboard.
2
Place the wall-mount bracket on the backboard or wall, and mark the location of the center
keyhole-shaped screw hole on the plywood backboard. See the figure
Figure 4
Wall-mount bracket
3
Install one #8 x 2 cm (#8 x 0.75 in.) round-head wood screw in the backboard.
Do not tighten the screw head against the backboard. Leave approximately 0.5 cm (0.25 in.) of
the screw exposed from the backboard.
4
Prepare the wall-mount bracket by removing the alignment tabs:
•
If this is the only unit in the BCM50 system, remove the alignment tabs on the right side of
the wall-mount bracket.
•
If this is the last unit on a BCM50 system with multiple units, remove the alignment tabs
on the left side of the wall-mount bracket.
5
Hang the wall-mount bracket on the mounting screw.
6
Install two #8 x 2 cm (#8 x 0.75 in.) round-head wood screws into the screw holes in the
wall-mount bracket. See the figure
7
Tighten the three wood screws against the wall-mount bracket.
8
Install two #8 x 2 cm (#8 x 0.75 in.) round-head wood screws into the screw holes in the cable
trough.
9
Repeat steps 2 to 8 for each additional unit.