Chapter 4 Installing the analog terminal adapter
25
Telephony Device Installation Guide
6
Plug the adapter into a standard ac outlet.
Mounting the ATA2
After you have correctly connected the ATA2, you can mount the unit on a wall.
To mount the ATA2 on a wall
1
Select a location for the ATA2 near the BCM50 main unit.
2
Allow 12.5 cm (5 in.) clearance for the line jack, terminal jack, and power supply connector.
3
Screw two 4-mm (#8) screws into the wall, 130 mm (5-1/4 in.) away from each other. Leave
6 mm (1/4 in.) of the two screws showing.
4
Align the slots at the back of the ATA2 unit over the screws.
5
Push the unit against the wall.
The line jack, terminal jack, and power supply connector must be at the top of the ATA2 (see
).
Figure 6
ATA2 back view
Test insertion loss measurement
The maximum loss for and ATA2-to-Central Office (CO) configuration must not exceed 10 dB
(see
).
Caution:
In North America, the ATA2 must be powered from a Class 2 power source that
is UL- and CSA-approved.
In Europe, the ATA2 must be powered from a Class II power source that is CE-marked.
Note:
If you are using 0.5 mm wire (24 AWG), select a location within
800 m (2600 ft.) of the BCM50 main unit.
Mounting keyhole slots
Summary of Contents for BCM50 2.0
Page 6: ...6 Contents NN40020 309 NN40020 309...
Page 18: ...18 Chapter 2 Device description NN40020 309 NN40020 309...
Page 28: ...28 Chapter 4 Installing the analog terminal adapter NN40020 309 NN40020 309...
Page 58: ...58 Chapter 7 Registering Nortel 20XX and 11XX IP telephones NN40020 309 NN40020 309...
Page 62: ...62 Chapter 8 Relocating telephones NN40020 309 NN40020 309...
Page 64: ...64 Appendix A ADID wiring chart NN40020 309 NN40020 309...
Page 70: ...70 Appendix D DTM wiring chart NN40020 309 NN40020 309...
Page 82: ...82 Appendix H GATM wiring chart NN40020 309 NN40020 309...