background image

5

establish a connection based upon the highest common capabilities. This feature is imple-
mented by using CLI commands and saves the network manager from having to go to
each workstation and switch to configure a "fixed" speed. 

ASCII configuration generator 

The ASCII configuration generator allows the configuration settings of the switch to be
displayed or saved to an external ASCII configuration file made up of a series of CLI
commands. This editable ASCII configuration file can then be uploaded to a switch from
an external file server.

The ASCII configuration file contains configuration settings for the following network
management applications:

• Core applications (system information, topology, etc.)

• Internet Protocol

• Multi-Link Trunking

• Port configuration

• Partial Spanning Tree configuration, including configuration of port priority and path cost

• VLAN configuration

• Quality of Service (QoS)

• RMON

Simple Network Time Protocol (SNTP)

Simple Network Time Protocol allows the synchronization of the switch or stack’s clock to
the real-time clock on the SNTP server. If the system (switch or stack) uses SNTP, then
SNTP time is used to time-stamp system log (Syslog) messages. If SNTP is not in use,
then the system uses a time-stamp relative to boot time.

Enhanced message logging

Several new features have been added for enhanced message logging. Log entries can now
be time-stamped with real time when the SNTP is in use. With the remote logging
feature, the system has the ability to copy internal system log messages onto a remote
Syslog server. Lastly, the Show Logging feature gives the administrator flexibility to view
and sort the login entries in forward or reverse manner.

Fail-safe stacking and resiliency 

A key differentiation for the BayStack 460 Switch is its resilient stacking feature. The
BayStack 460 Switch can stack up to eight units with a cascade stacking design, assuring
continuous uptime even if a switch in the stack should fail. A loop-back—or redundant
cascade cable—is used to seamlessly connect the entire stack to eliminate any single point
of failure 

(Figure 2)

Multi-Link Trunking 

Multi-Link Trunking (MLT) enables grouping of links between the BayStack 460 Switch
and another switch or a server to provide greater bandwidth with active redundant links. 

With Nortel Networks unique Distributed Multi-Link Trunking (DMLT) feature, trunked
ports can span multiple units of the stack for fail-safe connectivity to mission-critical servers
and the network center 

(Figure 3)

. This can provide bandwidth of up to 800 Mbps (when

used with 10/100 ports) or up to 8 Gbps (when used with Gigabit uplink ports) with active
redundant links in one trunk. Up to six trunks are supported per switch or stack. 

Figure 2. In the unlikely event of a
switch failure, the stack integrity
is maintained: cascade signals
loop back at point of failure.

Unit 8

Unit 7

Unit 6

Unit 5

Unit 4

Unit 3

Unit 2

Unit 1

Figure 3. Distributed Multi-Link
Trunking across stack for higher
bandwidth and fault tolerance

Multi-Gigabit
load-balancing
and failover
protection for
uninterrupted
access to the
network center

BayStack 460-24T-PWR Switch Stack

Passport 8600 Switch                        Server

Summary of Contents for BayStack 460-24T-PWR

Page 1: ... be transmitted over a single cable without using power outlets Flexible stacking across different BayStack switches a stack is managed as a single entity with a single IP address Simple software upgrades with single image for different switches Network availability with QoS features Fail safe stacking design assures continuous uptime Resilient connectivity for minimal network downtime Secure acce...

Page 2: ... BayStack 460 Switch is equipped with autosensing technology to automatically detect and support the speed and mode of a connected device The ports determine whether a connected device is operating at 10 Mbps or 100 Mbps and auto matically adjust to the optimal speed Each of the switched ports also automatically detect and support full duplex connections to servers power user end stations or other...

Page 3: ...s Policy Switch BayStack 470 48T and BayStack 470 24T BoSS simplifies network opera tions and provides the flexibility of stacking different switches in the same stack Simplified network operations BoSS simplifies network operations by reducing the number of steps required for switch software updates With BoSS you need to download only a single image from Nortel Networks for four different switch ...

Page 4: ...or SNMP Unit replacement feature In the unlikely event that a switch fails in a stack the affected switch can easily be replaced without disrupting the stack This feature provides the capability of upgrading a new unit with the configuration of the affected unit off line before adding the new unit to the stack The configuration of the affected switch may be copied from the Trivial File Transfer Pr...

Page 5: ... to copy internal system log messages onto a remote Syslog server Lastly the Show Logging feature gives the administrator flexibility to view and sort the login entries in forward or reverse manner Fail safe stacking and resiliency A key differentiation for the BayStack 460 Switch is its resilient stacking feature The BayStack 460 Switch can stack up to eight units with a cascade stacking design a...

Page 6: ...ssion 1000 Business Communications Manager Meridian and BayStack all provide the choices that allow enterprises from small and medium businesses to large campus infrastructures to deploy the solution that is right for them and offers the flexibility to implement infrastructure changes at their own pace Figure 5 depicts an example of a small to mid sized enterprise solution with the BayStack 460 Sw...

Page 7: ...P server The ASCII configuration file can be loaded automatically at boot time or on demand using the management systems console menus or CLI Once downloaded the configu ration file automatically configures the switch or stack according to the CLI commands in the file This feature allows the flexibility of creating command configuration files that can be used on several switches or stacks with min...

Page 8: ...abase is maintained on the authentication server not the switch EAP prevents network connectivity without password authorization for added security and control in physically non secure areas It is used where the network is not 100 percent physically secure or where physical security needs enhancement for example banks trading rooms or classroom training facilities EAP supports client access to the...

Page 9: ...er can be supplied to devices in case the power supply of the BayStack 460 fails Uninterruptible power supply support Using a BayStack 10 PSU will provide up to 75 watts of power to be supplied to devices in case there is an electrical outage Up to 15 minutes of battery life is provided this will vary depending on the amount of modules installed on the BayStack 10 Using an NES DC power system up t...

Page 10: ...vents on BayStack 460 Switches Tools such as Physical Topology View inform the network manager how a particular event is affecting the physical connectivity within the network The End Node Locate tool provides the ability to locate a failing end node and with one mouse click have access to the RMON statistics for the failing Ethernet port supporting that end node These solutions provide visual and...

Page 11: ... Switch s built in Web based management tools to facilitate QoS or alternatively Optivity Policy Services can be utilized for dynamic end to end enterprise wide policy and QoS management facilitated through the Common Open Policy Service COPS protocol Quality of Service provisioning With Optivity Policy Services policies can be created through a simple and intuitive drag and drop workflow Optivity...

Page 12: ...ts of traffic can be supported across one single mode fiber There are eight different wavelength GBIC options for 40 km and eight different wavelength GBIC options for 70 km Traffic Policing Traffic Policing enables provisioning of different levels of service by limiting traffic throughput at the ingress incoming port of the BayStack 460 Switch For example if a port is set to certain speeds such a...

Page 13: ...vices over multimode 550 m or 1 805 ft fiber optic cable 1000BASE LX Uses longwave 1 300 nm fiber optic connectors to connect devices over single mode 5 km or 3 1 mi or multimode 550 m or 1 805 ft fiber optic cable 1000BASE XD Uses single mode fiber to connect devices over distances up to 40 km or 31 mi depending on the quality of the cable 1000BASE ZX Uses single mode fiber to connect devices ove...

Page 14: ...ximum relative humidity non condensing Operating altitude Up to 3024 m 10 000 ft Storage altitude Up to 3024 m 10 000 ft Safety agency approvals UL listed UL 60950 CUL CAN CSA 22 2 No 60950 CB certificate and report with all national deviations IEC 60950 EN60950 Electromagnetic emissions summary Meets the following standards United States FCC CFR47 PART 15 SUBPART B Class A Canada ICES 003 ISSUE 3...

Page 15: ...nnector AA1419030 1 port 1000BASE CWDM Small Form Factor GBIC 1570nm Wavelength 40km LC connector AA1419031 1 port 1000BASE CWDM Small Form Factor GBIC 1590nm Wavelength 40km LC connector AA1419032 1 port 1000BASE CWDM Small Form Factor GBIC 1610nm Wavelength 40km LC connector AA1419033 1 port 1000BASE CWDM Small Form Factor GBIC 1470nm Wavelength 70km LC connector AA1419034 1 port 1000BASE CWDM S...

Page 16: ...hnology and infrastructure to enable value added IP data voice and multimedia services spanning Wireless Networks Wireline Networks Enterprise Networks and Optical Networks As a global company Nortel Networks does business in more than 150 countries More information about Nortel Networks can be found on the Web at www nortelnetworks com For more information contact your Nortel Networks representat...

Reviews: