background image

13

Technical specifications

Table 1. BayStack 460-24T-PWR Power over Ethernet Switch technical specifications

Performance specifications

Switch fabric 

2.56 Gbps

Frame forward rate (64-byte packets) 

Up to 3.2 million packets per second (pps) maximum, learned unicast traffic

Memory

16MB SDRAM

Port forwarding/filtering performance 

For 10 Mbps: 14,880 pps maximum

(64-byte packets) 

For 100 Mbps: 148,810 pps maximum

Address database size 

16,000 entries at line rate (32,000 entries without flooding)

Addressing 

48-bit MAC address

Frame length 

64 to 1518 bytes (IEEE 802.1Q Untagged)
64 to 1522 bytes (IEEE 802.1Q Tagged)

Data rate 

10 Mbps Manchester encoded or 100 Mbps 4B/5B encoded

Interface options

10BASE-T/100BASE-TX 

RJ-45 (8-pin modular) connectors for MDI-X interface

100BASE-FX 

SC and MT-RJ connectors for switched 100 Mbps (100BASE-FX) connections over 50/125 and 
62.5/125 micron multimode fiber optic cable (2 km/6562 ft. maximum distance)

1000BASE-SX (Shortwave Gigabit Fiber) MDA SC connectors for shortwave 850 nm fiber optic connections over multimode 

(550 m/1805 ft.) fiber optic cable

1000BASE-LX (Longwave Gigabit Fiber) MDA SC connectors for longwave 1300 nm fiber optic connections over single-mode 

(3km/9843 ft.) or multimode (550m/1805 ft.) fiber optic cable

1000BASE-CWDM (40km)

LC connectors for 1470-1610nm (in 20nm intervals)

1000BASE-CWDM (70km)

LC connectors for 1470-1610nm (in 20nm intervals) 

The BayStack 450-1GBIC MDA supports the following GBICs:

1000BASE-SX

Uses shortwave 850 nm fiber optic connectors to connect devices over multimode 
(550 m or 1,805 ft) fiber optic cable

1000BASE-LX

Uses longwave 1,300 nm fiber optic connectors to connect devices over single mode 
(5 km or 3.1 mi) or multimode (550 m or 1,805 ft) fiber optic cable

1000BASE-XD

Uses single mode fiber to connect devices over distances up to 40 km (or 31 mi), 
depending on the quality of the cable

1000BASE-ZX

Uses single mode fiber to connect devices over distances up to 70 km (or 43 mi), depending 
on the quality of the cable. The ports on this GBIC operate only in full-duplex mode

LED Indicators

Per-port status LEDs

10 or 100 Mbps port speed, Power over Ethernet detection, link status

System status LEDs

power, system, RPSU, stack mode, base mode

Network protocol and standards compatibility 

IEEE 802.3af compliant
IEEE 802.3 10BASE-T (ISO/IEC 8802 3, Clause 14)
IEEE 802.3u 100BASE-TX (ISO/IEC 8802-3, Clause 25)
IEEE 802.3u Autosensing (ISO/IEC 8802-3, Clause 28)
IEEE 802.1p (Prioritizing)
IEEE 802.1Q (VLAN Tagging)
IEEE 802.3z (Gigabit)
IEEE 802.1D (Spanning Tree Protocol)
IEEE 802.3ad (static/dynamic)
IEEE 802.1s *
IEEE 802.1w *
IETF DiffServ

RFC support 

RFC 791 (IP); RFC 792 (ICMP); RFC 793 (TCP); RFC 783 (TFTP); RFC 826 (ARP); RFC 768 (UDP); RFC 854 (TELNET); RFC 951 (Bootp); RFC 2236
(IGMPv2); RFC 1112 (IGMPv1); RFC 1945 (HTTP v1.0); RFC 2138 (RADIUS); RFC 1573 (IF-MIB); RFC 894 (IP over Ethernet); RFC 2674 (Q MIB); RFC
2030 (Simple NTP); RFC 1213 (MIB-II); RFC 1493 (Bridge MIB); RFC 2863 (Interfaces Group MIB); RFC 2665 (Ethernet MIB); RFC 2737 (Entity
MIBv2); RFC 2819 (RMON MIB); RFC 1757 (RMON); RFC 1271 (RMON); RFC 1157 (SNMP); RFC 2748 (COPS); RFC 2940 (COPS Clients); RFC 3084
(COPS Provisioning); RFC 2570 (SNMPv3); RFC 2571 (SNMP Frameworks); RFC 2572 (SNMP Message Processing); RFC 2573 (SNMPv3
Applications); RFC 2574 (SNMPv3 USM); RFC 2575 (SNMPv3 VACM)

Summary of Contents for BayStack 460-24T-PWR

Page 1: ... be transmitted over a single cable without using power outlets Flexible stacking across different BayStack switches a stack is managed as a single entity with a single IP address Simple software upgrades with single image for different switches Network availability with QoS features Fail safe stacking design assures continuous uptime Resilient connectivity for minimal network downtime Secure acce...

Page 2: ... BayStack 460 Switch is equipped with autosensing technology to automatically detect and support the speed and mode of a connected device The ports determine whether a connected device is operating at 10 Mbps or 100 Mbps and auto matically adjust to the optimal speed Each of the switched ports also automatically detect and support full duplex connections to servers power user end stations or other...

Page 3: ...s Policy Switch BayStack 470 48T and BayStack 470 24T BoSS simplifies network opera tions and provides the flexibility of stacking different switches in the same stack Simplified network operations BoSS simplifies network operations by reducing the number of steps required for switch software updates With BoSS you need to download only a single image from Nortel Networks for four different switch ...

Page 4: ...or SNMP Unit replacement feature In the unlikely event that a switch fails in a stack the affected switch can easily be replaced without disrupting the stack This feature provides the capability of upgrading a new unit with the configuration of the affected unit off line before adding the new unit to the stack The configuration of the affected switch may be copied from the Trivial File Transfer Pr...

Page 5: ... to copy internal system log messages onto a remote Syslog server Lastly the Show Logging feature gives the administrator flexibility to view and sort the login entries in forward or reverse manner Fail safe stacking and resiliency A key differentiation for the BayStack 460 Switch is its resilient stacking feature The BayStack 460 Switch can stack up to eight units with a cascade stacking design a...

Page 6: ...ssion 1000 Business Communications Manager Meridian and BayStack all provide the choices that allow enterprises from small and medium businesses to large campus infrastructures to deploy the solution that is right for them and offers the flexibility to implement infrastructure changes at their own pace Figure 5 depicts an example of a small to mid sized enterprise solution with the BayStack 460 Sw...

Page 7: ...P server The ASCII configuration file can be loaded automatically at boot time or on demand using the management systems console menus or CLI Once downloaded the configu ration file automatically configures the switch or stack according to the CLI commands in the file This feature allows the flexibility of creating command configuration files that can be used on several switches or stacks with min...

Page 8: ...abase is maintained on the authentication server not the switch EAP prevents network connectivity without password authorization for added security and control in physically non secure areas It is used where the network is not 100 percent physically secure or where physical security needs enhancement for example banks trading rooms or classroom training facilities EAP supports client access to the...

Page 9: ...er can be supplied to devices in case the power supply of the BayStack 460 fails Uninterruptible power supply support Using a BayStack 10 PSU will provide up to 75 watts of power to be supplied to devices in case there is an electrical outage Up to 15 minutes of battery life is provided this will vary depending on the amount of modules installed on the BayStack 10 Using an NES DC power system up t...

Page 10: ...vents on BayStack 460 Switches Tools such as Physical Topology View inform the network manager how a particular event is affecting the physical connectivity within the network The End Node Locate tool provides the ability to locate a failing end node and with one mouse click have access to the RMON statistics for the failing Ethernet port supporting that end node These solutions provide visual and...

Page 11: ... Switch s built in Web based management tools to facilitate QoS or alternatively Optivity Policy Services can be utilized for dynamic end to end enterprise wide policy and QoS management facilitated through the Common Open Policy Service COPS protocol Quality of Service provisioning With Optivity Policy Services policies can be created through a simple and intuitive drag and drop workflow Optivity...

Page 12: ...ts of traffic can be supported across one single mode fiber There are eight different wavelength GBIC options for 40 km and eight different wavelength GBIC options for 70 km Traffic Policing Traffic Policing enables provisioning of different levels of service by limiting traffic throughput at the ingress incoming port of the BayStack 460 Switch For example if a port is set to certain speeds such a...

Page 13: ...vices over multimode 550 m or 1 805 ft fiber optic cable 1000BASE LX Uses longwave 1 300 nm fiber optic connectors to connect devices over single mode 5 km or 3 1 mi or multimode 550 m or 1 805 ft fiber optic cable 1000BASE XD Uses single mode fiber to connect devices over distances up to 40 km or 31 mi depending on the quality of the cable 1000BASE ZX Uses single mode fiber to connect devices ove...

Page 14: ...ximum relative humidity non condensing Operating altitude Up to 3024 m 10 000 ft Storage altitude Up to 3024 m 10 000 ft Safety agency approvals UL listed UL 60950 CUL CAN CSA 22 2 No 60950 CB certificate and report with all national deviations IEC 60950 EN60950 Electromagnetic emissions summary Meets the following standards United States FCC CFR47 PART 15 SUBPART B Class A Canada ICES 003 ISSUE 3...

Page 15: ...nnector AA1419030 1 port 1000BASE CWDM Small Form Factor GBIC 1570nm Wavelength 40km LC connector AA1419031 1 port 1000BASE CWDM Small Form Factor GBIC 1590nm Wavelength 40km LC connector AA1419032 1 port 1000BASE CWDM Small Form Factor GBIC 1610nm Wavelength 40km LC connector AA1419033 1 port 1000BASE CWDM Small Form Factor GBIC 1470nm Wavelength 70km LC connector AA1419034 1 port 1000BASE CWDM S...

Page 16: ...hnology and infrastructure to enable value added IP data voice and multimedia services spanning Wireless Networks Wireline Networks Enterprise Networks and Optical Networks As a global company Nortel Networks does business in more than 150 countries More information about Nortel Networks can be found on the Web at www nortelnetworks com For more information contact your Nortel Networks representat...

Reviews: