Chapter 3 Installing the shelf, OADM, and OMUX
212257-B
4
Make the following network backbone connections (
Figure 17
):
•
Connect the network backbone east fiber optic cables to the east (left)
CWDM OMUX-4.
•
Connect the network backbone west fiber optic cables to the west (right)
CWDM OMUX-4.
Cabling an eight-channel CWDM OMUX
This section describes how to cable the following:
•
CWDM GBIC to a CWDM OMUX-8 (
Figure 18
)
•
CWDM OMUX-8 to network backbone interfaces (
Figure 18
)
To connect a CWDM OMUX-8:
1
Install the CWDM GBICs (wavelength specific) into the network device(s).
To install a CWDM GBIC, see Installing CWDM Gigabit Interface
Converters, part number 212256-B.
2
Clean all fiber optic connectors on the cabling (see
“Handling and cleaning
fiber optic equipment” on page 49
).
3
Connect the fiber optic cables from the CWDM GBIC TX and RX connectors
to the CWDM OMUX-8 RX and TX connectors (
Figure 18
).
Note:
The CWDM GBIC wavelength must match the CWDM OMUX-4
equipment connector wavelength.
The TX of one device must always connect to the RX of the next device.
Note:
The CWDM OMUX-8 located on the left side of the chassis
terminates the east network backbone connection. The CWDM OMUX-8
on the right side of the chassis terminates the west network backbone
connection. See
Figure 18
.
Note:
The wavelength of the CWDM GBIC must match the wavelength
of the CWDM OMUX-8 equipment connector.
Summary of Contents for 10292FA
Page 10: ...10 Figures 212257 B ...
Page 12: ...12 Tables 212257 B ...
Page 16: ...16 Preface 212257 B ...
Page 26: ...26 Chapter 1 Describing the optical routing system 212257 B ...
Page 46: ...46 Appendix A CWDM OADM specifications 212257 B ...
Page 48: ...48 Appendix B CWDM OMUX specifications 212257 B ...
Page 54: ...54 Appendix C Handling and cleaning fiber optic equipment 212257 B ...
Page 66: ...66 Glossary 212257 B ...
Page 70: ...70 Index 212257 B ...