important

attention inStallerS:

it is your responsibility to know this product 
better than your customer. this includes being 
able to install the product according to strict 
safety guidelines and instructing the customer 
on how to operate and maintain the equipment 
for the life of the product. Safety should 
always be the deciding factor when installing 
this product and using common sense plays 
an important role as well. pay attention to 
all safety warnings and any other special 
notes highlighted in the manual. improper 
installation of the furnace or failure to follow 
safety warnings could result in serious injury, 
death, or property damage.
these instructions are primarily intended to 
assist qualified individuals experienced in the 
proper installation of this appliance. Some 
local codes require licensed installation/
service personnel for this type of equipment. 
please read all instructions carefully before 
starting the installation. return these 
instructions to the customer’s package for 
future reference.

do not deStroy. pleaSe read careFully & 

Keep in a SaFe place For Future reFerence.

important SaFety inFormation ............... 2
air conditioner inStallation .................. 3

General Information ............................................ 3
Before You Install this Unit .................................. 3
Locating the Air Conditioner ............................... 3
Packaging Removal ............................................ 3
Ground Level....................................................... 3
Roof Mount ......................................................... 3
Connecting Refrigerant Tubing Between the
Indoor & Outdoor Unit ......................................... 4

electrical Wiring ......................................... 4

Pre-Electrical Checklist ....................................... 4
Line Voltage ........................................................ 4
Grounding ........................................................... 5
Thermostat Connections ..................................... 5

Start up & adJuStmentS ............................ 5

Pre-Start Check List ............................................ 5
Start-Up Procedures ........................................... 5

Air Circulation - Indoor Blower .......................... 5
System Cooling ................................................. 6
System Heating (optional) ................................. 6

air conditioner maintenance .................. 6
reFrigerant charging ............................... 6

Charging the Unit in AC mode ............................ 6
Application Notes for Using Charging Charts ..... 7

Figure 2. Charging Chart for 2 Ton Units ........... 7
Figure 3. Charging Chart for 2.5 Ton Units ........ 8
Figure 4. Charging Chart for 3 Ton Units ........... 8
Figure 5. Charging Chart for 3.5 Ton Units ........ 9
Figure 6. Charging Chart for 4 Ton Units ........... 9

component FunctionS ................................ 10
electrical diagramS .................................. 10

Figure 7. Wiring Diagram for 2, 2.5, 3, 3.5 Ton

Models (with PSC Motor) ................... 10

Figure 8. Wiring Diagram for 4 Ton Models

(with ECM Motor) ............................... 11

inStallation / perFormance checKliSt 12
replacement partS ...................................... 12

Summary of Contents for S6BF-024 Series

Page 1: ...allation Return these instructions to the customer s package for future reference DO NOT DESTROY PLEASE READ CAREFULLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE important SAFETY INFORMATION 2 Air cond...

Page 2: ...below must be followed during the installation service and operation of this unit Unqualified individuals should not attempt to interpret these instructions or install this equipment Failure to follow...

Page 3: ...nanceinformation and availability of maintenance contracts Please read all instructions before installing the unit Locating the Air Conditioner Survey the job site to determine the best location for m...

Page 4: ...rical connections in accordance with all applicable codes and ordinances Overcurrent protection must be provided at the branch circuit distribution panel and sized as shown on the unit rating label an...

Page 5: ...The thermostat should be mounted about 5 feet above theflooronaninsidewall DONOTinstallthethermostat on an outside wall or any other location where its operationmaybeadverselyaffectedbyradiantheatfrom...

Page 6: ...the system Add refrigerant and repeat Steps 1 through 3 until the system is correctly charged System Cooling 1 Set the thermostat s system mode to COOL and the fan mode to AUTO Gradually lower the the...

Page 7: ...sig Liquid Temperature F S6BF 024K Charging Chart Cooling Add refrigerant when below curve Remove refrigerant when above curve Figure 2 Before using these charts make sure the unit is in a stable oper...

Page 8: ...S6BF 030K Charging Chart Cooling Add refrigerant when below curve Remove refrigerant when above curve Figure 4 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 75 80...

Page 9: ...S6BF 042K Charging Chart Cooling Add refrigerant when below curve Remove refrigerant when above curve Figure 6 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 75 80...

Page 10: ...L2 OUTDOOR FAN MOTOR C S DUAL CAPACITOR R 3 1 2 START CAPAC START RELAY BLACK BLUE ORANGE YELLOW CONTACTOR YELLOW BLACK RED CRANKCASE HEATER OPTIONAL YELLOW BLACK SEE NOTE 6 RED OR YELLOW BLACK RED O...

Page 11: ...ction see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace air handler installation instructions for control circuit and optional relay transformer kits 7 Anti Short Cycle Timer...

Page 12: ...___________ Unit Installed Minimum clearances shown on page 3 YES NO Has the owner s information been reviewed with the customer YES NO Has the Literature Package been left with the unit YES NO REFRIG...