Figure 10. Gas Valve Label

A. This appliance does not have a pilot. It is equipped with 

an ignition device which automatically lights the burner.  

Do not try to light the burner by hand.

B. BEFORE OPERATING smell all around the appliance 

area for gas. Be sure to smell next to the fl oor because 

some gas is heavier than air and will settle on the fl oor.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any phone 

in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fi re 

department.

C. Use only your hand to push in or turn the gas control 

knob. Never use tools. If the knob will not push in or move 

by hand, do not try to repair it, call a qualifi ed service 

technician. Force or attempted repair may result in a fi re 

or explosion.

D. Do not use this appliance if any part has been under 

water. Immediately call a qualifi ed service technician 

to inspect the appliance and to replace any part of the 

control system and any gas control which has been 

under water.

  1. 

ATTENTION!

 Lire d’abord la liste des mesures de 

sécurité ci-dessus.

  2. Mettre le thermostat à la position minimale.

  3. Couper le courant électrique qui mène à l’appareil.

  4. Cet appareil ménager étant doté d’un système 

d’allumage automatique, ne pas essayer d’allumer le 

brûleur manuellement.

  5. Retirer le panneau/volet d’accès de commande 

(panneau supérieur s’il s’agit d’un modèle à deux 

panneaux).

  6. Réglez l’interrupteur de commande du gaz à la position 

“OFF”. (voir Figure 1).

  7. Attendre cinq (5) minutes pour s’assurer de la 

dissipation du gaz.

 

En cas d’odeur, ARRÊTER LE PROCÉDÉ. Suivre les 

instructions ci-dessus (Section B). En l’absence de 

toute odeur de gaz, avancer à l’étape suivante.

  8. Réglez l’interrupteur de commande du gaz à la position 

“ON”. (voir Figure 1).

  9. Remettre le panneau/volet d’accès de commande en 

place (panneau supérieur s’il s’agit d’un modèle à deux 

panneaux).

10. Rebrancher l’appareil sur le réseau électrique.

11. Ajuster le thermostat à la position désirée.

12. Si l’appareil ne fonctionne pas, suivre les “Directives 

d’arrêt” cidessous et appeler le technicien de service.

A. Cet appareil ménager n’a pas de veilleuse. II est doté 

d’un système d’allumage automatique. Ne pas essayer 

d’allumer le brûleur manuellement.

B. AVANT L’USAGE. Attention à une possible odeur de 

gaz surtout au niveau du plancher où les gaz les plus 

lourds ont la tendance de se concentrer.

EN CAS D’ODEUR DE GAZ.

•  Ne mettre en marche aucun appareil électrique.

•  Ne toucher à aucun commutateur électrique, ne pas 

employer le téléphone.

•  Quitter le bâtiment immédiatement et avertir la 

compagnie du gaz en utili sant le téléphone d’un voisin.

•  A défaut de la compagnie du gaz, avertir le service des 

pompiers.

C. Enfoncer ou faire tourner le robinet à gaz à la main 

seulement. Ne jamais utiliser d’outils. S’il n’est pas 

possible de faire tourner ou d’enfoncer le robinet à la 

main, ne pas essayer de le réparer. Faire appel à un 

spécialiste. Forcer ou tenter de réparer le robinet pourrait 

être à l’origine d’une explosion ou d’un incendie.

D. II est déconseillé d’utiliser cet appareil en contact 

prolongé avec l’eau. Faire inspecter ou remplacer 

toute commande par un technicien qualifi é si un des 

systèmes de contrôle du gaz s’est trouvé sous l’eau.

1. 

STOP! 

 Read the safety information above on this label.

2. Set the thermostat to the lowest setting.

3. Turn off all electrical power to the appliance.

4. The appliance’s ignition device automatically lights the 

burner. Do not try to light burner by hand.

5. Remove the control  access door/panel (upper door if 

two-door model).

6. Move the gas control switch to the “OFF” position. (See Figure 1)

7. Wait fi ve (5) minutes to clear out any gas. Then smell for gas,

including near the fl oor. If you smell gas, 

STOP!

 Follow “B” in above

information. If you don’t smell gas, go to the next step.

8. Move the gas control

switch to the “ON” 

position. (See Figure 1)

9. Replace the control 

access door/panel

(upper door if two

door model).

10. Turn on all electrical

power to the appliance.

11. Turn the thermostat to a

desired setting.

12. If the appliance will not

operate, follow the

instructions “To Turn Off Gas To Appliance” and call your

service  technician or gas supplier.

10186330

 (Replaces 7106740)

(10/17)

  1. Mettre le thermostat à la position minimale.

  2. Débrancher l’appareil en prévision de la réparation.

  3. Retirer le panneau/volet d’accès de commande 

(panneau supérieur s’il s’agit d’un modèle à deux 

panneaux).

4.  Réglez l’interrupteur de commande du gaz à la position 

“OFF”. Ne forcez pas. (voir Figure 1).

  5. Remettre le panneau/volet d’accès de commande en 

place (panneau supérieur s’il s’agit d’un modèle à deux 

panneaux).

POUR VOTRE SÉCURITÉ.

À LIRE AVANT L’EMPLOI

FOR YOUR SAFETY READ 

BEFORE OPERATING

  1. Set the thermostat to the lowest setting.

  2. Turn off all electrical power to the appliance if service is 

to be performed.

  3. Remove the control access door/panel (upper door if 

two-door model).

  4. Move the gas control switch to the “OFF” position. Do 

not use force. (See Figure 1)

  5. Replace the control access door/panel (upper door if 

two-door model).

ATTENTION!

 L’inobservation de ces instructions 

peut entraîner un incendie ou une explosion pouvant 

causer des dam mages à votre propriété à votre 

personne, ou la mort.

WARNING:

 If you do not follow these instructions 

exactly, a fi re or explosion may result causing property 
damage, personal injury, or loss of life.

TO TURN OFF

GAS TO APPLIANCE

DIRECTIVES D’ARRÊT

MODE D’EMPLOI

OPERATING INSTRUCTIONS

SWITCH

(L’INTERRUPTEUR )

Summary of Contents for R6GF Series

Page 1: ...plier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou...

Page 2: ...ion 17 System Cooling 17 System Heating 17 Verifying Adjusting Temperature Rise 17 Verifying Adjusting Firing Rate 18 Verifying Over Temperature Limit Control Operation 18 Verifying Burner Operation 1...

Page 3: ...g is required If repairs make it necessary for evacuationandcharging itshouldonlybeattempted by qualified trained personnel thoroughly familiar with this equipment Some local codes require licensed in...

Page 4: ...ctions and all applicable local codes Install this unit only in a location and position as specified on page 7 This unit is designed only for outdoor installations and should be located with considera...

Page 5: ...D gaugement conforme aux codes d installation locaux aux exigences du fournisseur de gaz et aux instructions d installation du fabricant Aclearanceofatleast36inchesfromthebloweraccesspanel andfromthe...

Page 6: ...nt pas suivies pour chacun des appareils raccord s au syst me de ventilationaumomentdesamiseenmarche celapeut entra ner une intoxication au monoxyde de carbone ou la mort Les tapes suivantes doivent t...

Page 7: ...fault condition If this control must be replaced use only factory authorized replacement parts See the list of Replacement Parts on page 21 Vent Termination This unit has been equipped with an integr...

Page 8: ...gned so that the return air to the unit is not less than 50 F 10 C during heating operation If a combination of indoor and outdoor air is used the ducts and damper system must be designed so that the...

Page 9: ...g enough to support the unit s weight The slab height must be a minimum of 2 5cm above grade and with adequate drainage See Figure 3 Remove and discard the horizontal supply and return duct covers loc...

Page 10: ...lectrique au g n rateur d air chaud avant de prod der aux travaux d entretein Au moment de l entretien des commandes tiquetez tous les fils avant de les d brancher S assurer de les raccorder correctem...

Page 11: ...rdancewith the instructions supplied with the thermostat and the indoor equipment These units use a special 2 speed compressor to achieve a high level of efficiency in a compact frame A 2 stage coolin...

Page 12: ...r system options With the blower installed and configured properly the furnace will gradually change speed in response to changes in system variables such as thermostat settings duct static filters et...

Page 13: ...noid damage from overheating conditions L Terminal Wiring White RodgersCompatibleThermostats TheLconnection is used to communicate Comfort Alert codes to compatible White Rodgersthermostats TheLtermin...

Page 14: ...al Electrical Code ANSI NFPA 70 or the CSA C22 1 Electrical Code Use the grounding lug provided in the control box for grounding the unit GAS SUPPLY PIPING WARNING FIRE OR EXPLOSION HAZARD Failure to...

Page 15: ...ectors A soap and water solution can be applied on each joint or union using a small paintbrush If any bubbling is observed the connection is not sealed adequately and must be retightened Repeat the t...

Page 16: ...al Gas R6GF X24K080XB R6GF X36K100XB MANIFOLD PRESSURE FOR NATURAL GAS INSTALLATIONS IN W C ALTITUDE ABOVE SEA LEVEL HEATING VALUE BTU CU FT ORIFICE SIZE 800 TO 899 FT 900 TO 999 FT 1 000 TO 1 100 FT...

Page 17: ...perly after 1 2 minutes lower the thermostat temperature set point an additional 3 4 degrees until the cooling system moves into 2nd stage or high cool operating mode The compressor and indoor blower...

Page 18: ...operating sequence page 19 NOTE The over temperature limit control should turn off the gas valve within approximately four minutes exact time depends on the efficiency of the close off when blocking t...

Page 19: ...on step 6 begins If no flame is sensed on the fifth try for ignition the furnace control is locked and the red LED will flash 4 times repetitively The thermostat must be opened for at least ten second...

Page 20: ...eginning of each heating and cooling season or more frequently if required Inspectthecondensatedrainandoutdoorcoilatthebeginning of each cooling season Remove any debris Clean the outdoorcoilandlouver...

Page 21: ...ches separate the ground joint union in the gas supply piping at the unit 7 Remove the piping between the gas valve and the ground joint union if applicable 8 Remove all screws securing the burner ass...

Page 22: ...Speed Blower call OFF SYSTEM STATUS CFM LED STATUS YELLOW NOT USED OFF automatically opens and regulates the gas pressure in the manifold See Figure 8 page 18 Over Temperature Limit Control The over t...

Page 23: ...rizontal Supply Duct Opening Horizontal Return Duct Opening 4 0 1 75 9 75 24 75 16 0 Condensing Coil 13 5 16 0 16 0 C 13 5 Figure 9 Unit Dimensions Table 8 Center of Gravity Unit Shipping Weights MODE...

Page 24: ...ormal 1170 Normal 1700 10 990 10 1290 10 1870 TAP C 10 900 TAP C 10 1140 TAP C 10 1620 Normal 1000 Normal 1270 Normal 1800 10 1100 10 1400 10 1980 TAP D 10 1080 TAP D 10 1260 TAP D 10 Normal 1200 Norm...

Page 25: ...9 86 42 209 419 88 41 205 409 90 40 200 400 92 39 196 391 94 38 191 383 96 38 188 375 98 37 184 367 100 36 180 360 102 35 176 353 104 35 173 346 106 34 170 340 108 33 167 333 110 33 164 327 112 32 161...

Page 26: ...compagnie du gaz en utili sant le t l phone d un voisin A d faut de la compagnie du gaz avertir le service des pompiers C Enfoncer ou faire tourner le robinet gaz la main seulement Ne jamais utiliser...

Page 27: ...UNIT CONTROL BOARD W1 W2 C R G Y Y2 0 DEHUM P2 1 5 HUM LINE XMFR CONT EAC COOL PARK1 PARK2 HI HEAT LO HEAT NEUTRALS AUTO HEAT STAGE 10 5 NONE HOT SURFACE IGNITION VARIABLE SPEED BLOWER CONTROL BOARD C...

Page 28: ...208 230 Volt Single Phase Packaged Two Stage Heat Two Stage Electric Air Conditioner 60Hz WIRING DIAGRAM NOTES 1 Disconnect power before servicing 2 For supply connections use copper conductors only...

Page 29: ...Single Phase Packaged Two Stage Heat Two Stage Electric Air Conditioner 60Hz WIRING DIAGRAM NOTES 1 Disconnect power before servicing 2 For supply connections use copper conductors only 3 Not suitabl...

Page 30: ...fective Condenser coil is dirty Liquid line restriction filter drier blocked if present in system Thermostat is malfunctioning Solenoid plug not connected Y2 not wired at Comfort Alert Check thermosta...

Page 31: ...s flashing at same time means control circuit voltage is too low for operation Table 14 LED Diagnostics Continued Table 15 Module Wiring Troubleshooting MISWIRED MODULE INDICATION RECOMMENDED TROUBLES...

Page 32: ...repeat steps 1 through 3 until the system is correctly charged Charging Charts Application Notes This equipments cooling system contains refrigerant under high pressure always use safe practices when...

Page 33: ...igerant when below curve Remove refrigerant when above curve Figure 15 Charging Chart for 2 Ton Units Figure 16 Charging Chart for 3 Ton Units Liquid Pressure psig Liquid Temperature F R6GF X36 Chargi...

Page 34: ...igerant when below curve Remove refrigerant when above curve Figure 18 Charging Chart for 5 Ton Units Figure 17 Charging Chart for 4 Ton Units Liquid Pressure psig Liquid Temperature F R6GF X48 Chargi...

Page 35: ...35...

Page 36: ...nit YES NO ELECTRICAL SYSTEM Electrical connections tight YES NO Line voltage polarity correct YES NO Rated Voltage VOLTS L1 L2 Volts __________________________________________________________________...

Reviews: