Nortek C6BA Series Installation Instructions Manual Download Page 7

7

Table 1. 

C6 Upflow Coil Specifications

C6 CASED COIL SPECIFICATIONS

MODEL: C6BA (1)(2)

T24-A X24-A

T30-A X30-A

X35-A

T24-B X24-B

X26-B

T30-B X30-B

X35-B

T36-B X36-B

T42-B X42-B

T36-C X36-C

T42-C X42-C

T48-C X48-C

T60-C X60-C

T42-D X42-D

T48-D X48-D

T60-D X60-D

N

omi

N

al

 C

apa

C

ity

 B

t

UH 

(3)

24,000

30,000

36,000

24,000

24,000

30,000

36,000

36,000

42,000

36,000

42,000

48,000

60,000

42,000

48,000

60,000

m

eteri

N

g

 D

evi

C

e

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

N

omi

N

al

 a

irflow

 (C

fm

)

800

1,000

1,000

800

1,200

1,000

1,200

1,200

1,400

1,200

1,400

1,600

2,000

1,400

1,600

2,000

w

 - 

w

iD

t

H

 (

iN

.)

14 1/2

14 1/2

14 1/2

17 1/2

17 1/2

17 1/2

17 1/2

17 1/2

17 1/2

21 

21 

21 

21 

24 1/2

24 1/2

24 1/2

H - H

eig

H

t

 (

iN

.)

20 3/4

20 3/4

20 3/4

20 3/4

26 3/4

20 3/4

20 3/4

26 3/4

26 3/4

26 3/4

26 3/4

30 1/4

30 1/4

30 1/4

30 1/4

30 1/4

H

l - H

eig

H

t

 

of

 l

iq

U

iD

 l

iN

e

 (

iN

.)

17 1/2

17 1/2

17 1/2

17 1/2

23 1/2

17 1/2

17 1/2

23 1/2

23 1/2

23 1/2

23 1/2

27 

27 

27 

27 

27 

HS - H

eig

H

t

 

of

 S

UC

tio

N

 l

iN

e

 (

iN

.)

15 1/2

15 1/2

15 1/2

15 1/2

21 1/2

15 1/2

15 1/2

21 1/2

21 1/2

21 1/2

21 1/2

25 

25 

25 

25 

25 

C

o

NN

e

C

tio

N

 - 

l

iq

U

iD

 l

iN

e

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

C

o

NN

e

C

tio

N

 - S

UC

tio

N

 l

iN

e

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

7/8

7/8

7/8

7/8

7/8

7/8

7/8

H

orizo

N

tal

 D

rai

N

 K

it

 (4)

920265

920265

920265

920265

920266

920265

920265

920266

920266

920266

920266

920267

920267

920267

920267

920267

C6 HORIZONTAL CASED COIL SPECIFICATIONS

MODEL: C6BH (1)(2)

T24-A X24-A

T30-A X30-A

X35-A

T24-B X24-B

X26-B

T30-B X30-B

X35-B

T36-B X36-B

T42-B X42-B

T36-C X36-C

T42-C X42-C

T48-C X48-C

T60-C X60-C

T42-D X42-D

T48-D X48-D

T60-D X60-D

N

omi

N

al

 C

apa

C

ity

 B

t

UH 

(3)

24,000

30,000

36,000

24,000

24,000

30,000

36,000

36,000

42,000

36,000

42,000

48,000

60,000

42,000

48,000

60,000

m

eteri

N

g

 D

evi

C

e

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

N

omi

N

al

 a

irflow

 (C

fm

)

800

1,000

1,000

800

1,200

1,000

1,200

1,200

1,400

1,200

1,400

1,600

2,000

1,400

1,600

2,000

w

 - 

w

iD

t

H

 (

iN

.)

14 1/4

14 1/4

14 1/4

17 1/2

17 1/2

17 1/2

17 1/2

17 1/2

17 1/2

21 

21 

21 

21 

24 1/2

24 1/2

24 1/2

H - H

eig

H

t

 (

iN

.)

26 3/4

26 3/4

26 3/4

26 3/4

20 3/4

26 3/4

26 3/4

26 3/4

26 3/4

26 3/4

26 3/4

30 1/4

30 1/4

30 1/4

30 1/4

30 1/4

H

l - H

eig

H

t

 

of

 l

iq

U

iD

 l

iN

e

 (

iN

.)

23 1/2

23 1/2

23 1/2

23 1/2

17 1/2

23 1/2

23 1/2

23 1/2

23 1/2

23 1/2

23 1/2

27 

27 

27 

27 

27 

HS - H

eig

H

t

 

of

 S

UC

tio

N

 l

iN

e

 (

iN

.)

21 1/2

21 1/2

21 1/2

21 1/2

15 1/2

21 1/2

21 1/2

21 1/2

21 1/2

21 1/2

21 1/2

25 

25 

25 

25 

25 

C

o

NN

e

C

tio

N

 - 

l

iq

U

iD

 l

iN

e

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

C

o

NN

e

C

tio

N

 - S

UC

tio

N

 l

iN

e

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

7/8

7/8

7/8

7/8

7/8

7/8

7/8

(1) Refer to sales specification sheets for Listed/Certified combinations of equipment and required accessories. (2) X in the model description designates factory installed TXV for R-410a refrigerant.       T in the model description designates factory installed TXV for R-22 refrigerant. (3) Refer to the current ARI Directory for certified ratings of split systems. (4) Not required for "H" horizontal ready coils.

Table 2. 

C6 Horizontal Coil Specifications

Summary of Contents for C6BA Series

Page 1: ...ntion to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings could result in serious injury death or pro...

Page 2: ...Unqualified individuals should not attempt to interpret these instructions or install this equipment If you do not posses mechanical skills ortools callyourlocaldealerforassistance Under no circumsta...

Page 3: ...ssaryclose offplatesaroundtherefrigerant lines and drain line where required Reinstall all inner and outerpanelsofthefurnace airhandlerthatwerepreviously removed when installing the indoor coil Upflow...

Page 4: ...2 Verify pressurization by depressing the Schrader valve on the end of the liquid line Listen for any escaping gas If there is no pressure test the coil for leakage If leakage is found clearly mark th...

Page 5: ...y the grommet is evenly aligned around the tube and securely positioned in the door cutout COMPLETING THE INSTALLATION 1 Position the drain pan so the connections are aligned with the corresponding kn...

Page 6: ...Coil Dimensions W HS HL H 5 8 4 17 3 4 20 3 4 FRONT VIEW TOP VIEW Distributor Thermal Expansion Valve TXV Door TXV Retaining Nut Liquid Line Stub w Screen Accessory Retaining Nut Grommet Figure 3 TXV...

Page 7: ...IONS MODEL C6BH 1 2 T24 A X24 A T30 A X30 A X35 A T24 B X24 B X26 B T30 B X30 B X35 B T36 B X36 B T42 B X42 B T36 C X36 C T42 C X42 C T48 C X48 C T60 C X60 C T42 D X42 D T48 D X48 D T60 D X60 D N omin...

Page 8: ...8...

Page 9: ...on tous les avertissements de s curit et toute autre remarque sp ciale donn e dans le manuel L installation inappropri e de la fournaise ou le non respect des avertissements de s curit risque d entra...

Page 10: ...endant son installation son entretien et son utilisation Les personnesnonqualifi esnedoiventpastenterd interpr ter ces instructions ou d installer cet quipement Si vous ne poss dez pas les comp tences...

Page 11: ...la Liste des pi ces de rechange pour les num ros de pi ces disponibles Installez les plaques de fermeture requises autour des conduites de frigorig ne et conduites d vacuation au besoin R installez to...

Page 12: ...bout de la conduite de liquide coutez pour d tecter toute fuite de gaz S il n y a pas de pression v rifiez s il y a une fuite dans le serpentin Si une fuite est d tect e marquez clairement l emplaceme...

Page 13: ...nt dans l entr e d fon able de la porte FINALISATION DE L INSTALLATION 1 Positionnez le plateau de d givrage de mani re ce que les raccords soient align s avec les d bouchures correspondants 2 V rifie...

Page 14: ...4 20 3 4 VUE AVANT VUE DE DESSUS Distributeur D tendeur thermostatique TXV Serrure crou de retenue du d tendeur thermostatique Embout de la conduite de liquide avec tamis crou de retenue d accessoire...

Page 15: ...X35 A T24 B X24 B X26 B T30 B X30 B X35 B T36 B X36 B T42 B X42 B T36 C X36 C T42 C X42 C T48 C X48 C T60 C X60 C T42 D X42 D T48 D X48 D T60 D X60 D Capacit nominale BTUH 3 24 000 30 000 36 000 24 0...

Page 16: ...ubjecttochangewithoutnoticeorincurringobligations 10 22 O Fallon MO Nortek Global HVAC LLC 2022 All Rights Reserved Sp cifications et illustrations sujettes changements sans pr avis ou sans aucune obl...

Reviews: