Copyright
©
2017 Nortek Security & Control LLC
25
Z-Wave Con
fi
gura
Ɵ
on Parameters
The GC-TBZ48L supports the following Con
fi
gura on Parameters.
Confi guration
Parameter #
Description
Read values
Write values
1
System Type
4
0 = Standard
1 = Heat Pump
0 = Standard
1 = Heat Pump
2
Fan Type
4
0 = Gas (No fan w/Heat)
1 = Electric (Fan w/Heat)
0 = Gas (No fan w/Heat)
1 = Electric (Fan w/Heat)
3
Change Over
Type
4
0 = CO w/cool
1 = CO w/heat
0 = CO w/cool
1 = CO w/heat
4
2
nd
Stage Heat
Enable
4
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
5
Aux Heat Enable
4
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
6
2
nd
Stage Cool
Enable
4
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
7
C/F Type
0 = Cen grade
1 = Fahrenheit
0 = Cen grade
1 = Fahrenheit
8
MOT
5
5-9
5-9
9
MRT
5
3-9
3-9
10
Setpoint H/C Delta
3-15
3-15
11
H Delta Stage
1 ON
1-6
1-6
12
H Delta Stage
1 OFF
0-5
0-5
13
H Delta Stage
2 ON
2-7
2-7
14
H Delta Stage
2 OFF
0-6
0-6
15
H Delta Aux ON
3-8
3-8
16
H Delta Aux OFF
0-7
0-7
17
C Delta Stage 1 ON
1-6
1-6
18
C Delta Stage 1
OFF
0-5
0-5
19
C Delta Stage 2 ON
2-7
2-7
20
C Delta Stage 2
OFF
0-6
0-6
21
Mechanical Status
3
MECH_H1
0x0001
n/a
MECH_H2
0x0002
MECH_H3 0x0004
MECH_C1 0x0008
MECH_C2 0x0010
PHANTOM_F 0x0020
MECH_F 0x0040
MANUAL_F 0x0080
reserved
0x0100
22
SCP Status
3
STATE_HEAT
0x01
n/a
STATE_COOL
0x02
STATE_2ND
0x04
STATE_3RD
0x08
STATE_FAN
0x10
STATE_LAST
0x20
STATE_MOT
0x40
STATE_MRT
0x80