Z-Wave controllers from various manufacturers may support the Z-Wave Thermostat General V2
Device class used by the GoControl Z-WAVE Thermostat. The following procedure will allow the
thermostat to be added to a Z-Wave network.
NOTE:
Before adding the thermostat to a Z-Wave Network, check that it does not already belong to
one by viewing the Node ID (ZNID) located in the Thermostat Info screen. An uninstalled thermostat
should show zeros for the Node ID (000). Consult your controller’s user manual for details on
removing a device from a Z-Wave network.
Figure 16.
Z-Wave Menu Setup
General Programming Procedure (for controllers suppor ng the thermostat device class):
1. Set your primary controller to Include, add or Install mode, to add the thermostat as a node on
your network (see your controller’s user manual for detailed instruc ons).
2. Press any bu on to take thermostat out of sleep mode.
3. Press and hold
FAN
bu on for 5 seconds.
SETUP
will be displayed in the status display line.
4. Scroll to “Z-Wave” using
bu ons. Press
SELECT.
5. When prompted by your Z-Wave controller, Press the
YES
bu on in the Z-Wave Install screen.
6. Press
SELECT
(mode bu on) to add thermostat to network.
7. Display line should
fl
ash
WAIT
then
SUCCESS
if Z-Wave connec on is made.
8. If Z-Wave does not connect to controller,
WAIT
, then
FAIL
will
fl
ash in status display line.
9. If thermostat fails to connect, repeat Steps three (3) thru (7) to re-try connec ng.
Your controller will indicate the thermostat was successfully added to its network (see your
controller’s user manual for details). Also, you can check if the thermostat was successfully added
to the network by checking the ZHID (Home ID) and ZNID (Node ID) located in the Thermostat Info
screen.
For other speci
fi
c tasks such as adding the thermostat to Scenes or Groups, or dele ng the thermostat
from an exis ng network, refer to the Z-Wave controller instruc ons.
Inclusion and Exclusion
Inclusion or exclusion is started by pu ng the controller into add node or remove node state
and performing the General Programming Procedure outlined above. As part of the process, the
thermostat sends a node informa on frame at normal power. Low power inclusion or low power
exclusion is not possible.
CAUTION:
Do not install ba eries and temporarily power the thermostat from 24VAC to include onto
a Z-Wave network. Shortened ba ery life may occur when 24VAC power is removed.
MODE
FAN
Select
Done
z-wave
USE THE
BUTTONS TO CHANGE
TO THE DESIRED MENU
ITEM, THEN PRESS
SELECT
MENU CHOICES
ARE DISPLAYED IN THE
STATUS DISPLAY LINE
PUSH AND HOLD
FOR 5 SECONDS
76
Summary of Contents for Gocontrol GC-TBZ48L
Page 31: ...Copyright 2017 Nortek Security Control LLC 29 ...
Page 32: ...10006936 C ...