8.5 The display screen for program 420
For a military NiCd battery (manufacturer independent) = Type 20 with a nominal voltage of 24
V
and 4
Ah the testing cycle = Treatment 4 is shown as an example.
Program No 420 follows after entering the user specific data. Confirm with
and the following
display is shown:
8.5.1
Program 420 Step 1
NiCd battery (manufacturer independent)
Program:
Maintenance
P420:S1: DISCHARGE 1
24.06V
04.00A
00.5Ah
006MIN
15.01.15 19:43:00
--.-°C
1
Program number
2
Step number
= S1
3
Step type
= DISCHARGE 1
4
19:43:00
= present time
5
24.06
V
= present battery voltage
6
04.00
A
= present discharging current
7
000.5
Ah
= present capacity taken at stage of print
8
+006
MIN
= time span
9
--,-
C
= no active temperature measuring
10
Maintenance
= kind of treatment
5
6
7
4
3
2
1
8
9