![Nortec UL60 Operation Manual Download Page 119](http://html1.mh-extra.com/html/nortec/ul60/ul60_operation-manual_1705755119.webp)
11 Used terms
9.2 Changing of printer paper roll:
©
Nortec Electronics 2018
119
Cell voltage
The term „cell voltage“ is used in connection with the number of cells of the treated battery to describe
a program related switching voltage within charging or discharging programs.
Cell voltage is not equal to nominal voltage!
Reconditioning
Reconditioning is a process to recover reversible capacity losses on cells imbalanced during shallow
cycling and discharge voltage reduction by continuous float charge, or storage.
Testcycle / tests
In order to find out the real capacity of the battery and to make the battery ready for further use
“Testcycle /tests” means a cycle of discharge-charge-discharge-charge.
Charging
“Charging” means a non-damaging full-charge within the shortest possible time. Charging is done in a
way that the battery can be used immidiately after the charging.
Note
Terms which are not described here are explained in the procedures for each program use
(for example IU-charging, IUI-charging or similar).
Battery manufacturer
For the programs, which are marked with a manufacturer name the battery treatments follow the
instructions of the following battery manufacturers:
Hawker ®
Saft
НКБН (NKBN)
MarathonNorco Aerospace®
The following programs were created with the utmost care according to the maintenance
manuals of the battery manufacturers, but are offered without guarantee. Before applying the
below programmed programs this must be checked for compliance with currently valid main-
tenance manuals of the battery manufacturer. If in doubt or in case of deviations the currently
valid maintenance manual of the battery manufacturer always applies.