![Nortec UL10 Operation Manual Download Page 66](http://html1.mh-extra.com/html/nortec/ul10/ul10_operation-manual_1705753066.webp)
CHARGER / DISCAHRGER UL10
OPERATION MAUNAL
©
NorTec Electronics 2014
65
7.28 Program 520. Direct current charging – enclosed aircraft nickel-
cadmium battery
Stage
name
Maximum
duration
Program
number
520
Operation
number
5
Operation
type
Direct
current
charging
Battery type
Nickel-cadmium
Manufacturing
process
Fused
electrodes
Access
to
valves
open
Battery
type
20
Minimum
battery
capacity
4 Ah
Maximum
battery
capacity
50 Ah
Minimum
battery
voltage
1.2
Maximum
battery
voltage
31.2
Maximum number of batteries
26
Stage 1 (
S1
)
I-Charge Current
free selection
Stage 1 (
S1
)
I-Charge Umax
=
V/battery
free selection
Stage 1 (
S1
)
I-Charge time
free selection
Program 521, 530 and 531 are identical.