![Nortec UL10 Operation Manual Download Page 61](http://html1.mh-extra.com/html/nortec/ul10/ul10_operation-manual_1705753061.webp)
CHARGER / DISCAHRGER UL10
OPERATION MAUNAL
60
©
NorTec Electronics 2014
7.23 Program 430. Maintenance – enclosed aircraft nickel-cadmium battery
type SAFT
Stage
name
Maximum
duration
Program
number
430
Operation
number
4
Operation
type
Maintenance
Battery type
Nickel-cadmium
Manufacturing
process
Fused
electrodes
Access
to
valves
open,
type
SAFT
Battery
type
30
Minimum
battery
capacity
4 Ah
Maximum
battery
capacity
50 Ah
Minimum
battery
voltage
1.2 V
Maximum
battery
voltage
31.2 V
Maximum number of batteries
26
Stage 1 (
S1
)
I-Charge
1
Current
=
x
С
(A)
х
= 1
75 min.
Stage 1 (
S1
)
I-Charge
1
Umax
=
V/battery
1.57
75
min.
Stage 2 (
S2
)
Topping charge 1
Current = x
С
(A)
х
= 0.1
240 min.
Stage 2 (
S2
)
Topping charge 1
Measurement of
Sound signal
225 min.
voltages
of
individual
batteries
Break
30
min
Stage 4 (
S4
)
Discharge
Discharge
current
х
= 1
54 min.
а
= x
С
(A)
Stage 4 (
S4
)
Discharge
Discharge
depth 1
54
min.
V/battery
Stage 4 (
S4
)
Discharge
Measurement
of
Sound signal
54 min.
voltages of individual
batteries