Max. permissible operating pressure as indicated on the pressure manometer 1.8 bar.
·
Max. permissible operating temperature 40°C
·
Connection of a heat exchanger only permitted in the free outlet to the swimming pool.
Not via the filter system, otherwise max. operating pressure or max. operating
temperature may be exceeded.
·
Do not install deeper than 3 - 4 m below the level of the pool water.
·
Direct connection of the water pipe is only permitted with special precautions (pressure
reducer) which prevent a pressure higher than 2.0 bar.
·
Clamping ring may only be tightened when the filter vessel is depressurised (filter pump
switched
off).
·
Before switching on the filter pump, check the correct seating of the clamping ring with
an even overlap of 5
–
10 mm.
·
The filter tank is a pressure vessel with risk of overpressure.