12
SW
Side Wall to Side
17 inch 432 mm
SFC
Side Wall to Flue Collar 30 inch 762 mm
BW
Back Wall to Unit
12 inch 305 mm
BFC Back Wall Flue Collar
15 inch 381 mm
Fig 8
Fig 8a
SW
Side Wall to Side
30 inch 762 mm
SFC
Side Wall to Flue Collar 37 inch 940 mm
BW
Back Wall to Unit
12 inch 305 mm
BFC Back Wall Flue Collar
15 inch 381 mm
SWC
Side Wall to Corner
10 inch 254 mm
SFC
Side Wall to Flue Collar 23 inch 584 mm
BWC
Back Wall to Corner
10 inch 254 mm
BFC Back Wall Flue Collar
23 inch 584 mm
Fig 8 No Side Window
Fig 8a With Side Window
Fig 8c Corner installation
Clearance to Combustible Materials
SW
SW
SFC
SFC
BW
BW
BFC
BFC
Heat shield must be installed on the back of the stove at all times.
BWC
BWC
SFC
SWC
Fig 8c