Page 1: ...Glamox Production GmbH Co KG Glasower Weg 5 17166 Teterow Germany Doc 7SL2002001 Rev 04 www glamox com gmo DCN 22880 Date 2019 11 07 USER S MANUAL SEARCHLIGHTS XENON R50 ...

Page 2: ...elongs to the product Serie no ______________ Controlled by ______________ Date ______________ Technical Manual for Xenon searchlight XS 500 R50 XS 1000 R50 XS 1600 R50 XS 2000 R50 XS 3000 R50 1 x 230 VAC 1 x 115 VAC ...

Page 3: ...cal Department can be contacted as follows Glamox Production GmbH Co KG Glasower Weg 5 17166 Teterow Germany www glamox com gmo We would also like to use this opportunity to thank you for choosing Norselight as your supplier of marine searchlights The guarantee is only valid against production faults It do not cover damage caused by transportation damage due to disregard of this technical Manual o...

Page 4: ... Xenon Searchlight 16 2 2 Main Operation Panel 17 2 3 Slave Operation Panel 17 2 4 Wireless Operation Panel 18 2 5 Switch 19 2 6 Access Point 20 3 Installation 21 3 1 Mechanical installation 21 3 2 Electric installation 21 3 3 BUS installation 22 3 4 Start up procedure 22 4 Operation 23 4 1 Operation Panels function 23 4 2 Change of the lamp 24 4 3 General Searchlight Maintenance 24 5 Spare Parts ...

Page 5: ...ration Panels option BUS communication Lamp ON OFF Joystick for sweep and tilt horizontal and vertical movement Speed regulator for sweep and tilt Focus light beam adjustment LED Indication for searchlight position 360o Searchlight ID number End position function Designed for console or bulkhead mounting from front DIM LED intensity on Main Operation Panel Slave Operation Panel Option It contains ...

Page 6: ...6 Main and Slave Operation Panel ...

Page 7: ...7 Wireless Operation Panel ...

Page 8: ...tely controls the searchlights with R50 motor unit The control system is based on TCP IP technology were several different Operator Panel can control separately up to 9 searchlights of Xenon or Halogen The system is connected to the same network through LAN switch to connect to a network of searchlights Control panels both hard wired and wireless are fitted into a standard solution 1 4 The Etherne...

Page 9: ... new design Based on TCP IP technology Waterproof quick disconnect RJ 45 connector Custom made for Offshore Supports masts from 1 to 2 diameter 200m Area wireless coverage IP66 RoHs FCC CE IC Complaint 40 to 80 degree operation temperature Package Include 1x Wireless receiver unit 1x PoE Power supply 1x 8dBi wireless antenna Network cables not included ...

Page 10: ...ndicates that the searchlight is positioned straight forward compared to the searchlight 0o position The searchlight has an 180o movement to the left and right end position in total 360 o To calibrate the position indicator you simply use the joystick on the Main Control Panel to turn the searchlight to end stop to both left and right end position 1 6 Main Control Panel position indicator versus s...

Page 11: ...11 1 7 Power Supply Rectifiers ...

Page 12: ...ier 1 Lamp ON OFF switch IMPORTANT NOTE DO NOT USE THIS SWITCH FOR THE REMOTE CONNECTION 2 Mains on LED 3 Lamp current potentiometer Adjusting the lamp output current 4 Input terminal board 5 Output terminal board Used to connect the lamp power cables 6 Current LED bar Indicating the output current level 12A to 30A 7 Lamp ON terminal board 8 Remote lamp ON OFF terminal board 9 Igniter insertion te...

Page 13: ...gulation and a special circuit to avoid the lamp turn off during the tap switching The cabinet equipped with carrying handles permits an easy inspection of the inside components Weight 63 kg Further instructions in Installation guide for Rectifier Control devices 1 Mains fuse F1 2 ON OFF switch and high low diode protection C2 C7 C8 lamp output current setting Q1 3 6 steps lamp output current sett...

Page 14: ...3000W short arc Xenon lamps meeting all the requirements of lamp manufacturers to ensure correct operation long life to the lamp and high reliability Weight 18 kg Further instructions in Installation guide for Rectifier Control devices 1 Synoptic panel 2 Output terminal block 3 Input terminal block 4 RS232 connector 5 Auxiliary connector ...

Page 15: ...N3 80 101 kg and N3 150 154 kg Further instructions in Installation guide for Rectifier Component layout 1 Adjustment hand wheel 2 Magnetic shunt MS 3 Transformers T1 to T3 4 Circuit breaker QF 5 Auxiliary contact S2 6 Output filter capacitors C7 C8 7 Auxiliary filter AF L on request for N3 50E N3 80E N3 100E models 8 Protection capacitors C1 to C6 9 Ignition relay A1 10 Silicon diodes D1 to D6 11...

Page 16: ... lm Focus distance 89mm 3 5 70mm 2 3 4 82 6 mm Parabolic silver plated glass reflector Dia 305mm 12 Dia 356mm 14 457 mm 18 Divergence 2 7 3 8 2 7 3 8 Range at 1 lux Theoretical calculation 4600m 6400m 7 200 m 9200 m 11500 m Vertical movement Speed Range 1 10 sec 25 30 2 8 sec 25 Horizontal movement Speed Range 1 20 sec 180 1 18 sec 180 Type of Power Supply 115V EX 30 G 1 NP 0725 PX 50N NP 0725 On ...

Page 17: ...ensing Compass Safe distance Standard 40 cm Steering 30 cm Cerificates DNV Standard IEC 60945 Ed4 2002 08 Number of panels Standard max 2 pcs to each Main Operation Panel Network Direct connection to Main Operation Panel Interface Phoenix he she connector 3 81 pitch Cable 5 wire shielded connected 1 to 1 Power Requirements N A Physical Characteristics Casing IP22 protection Dimensions WxHxD 96x96x...

Page 18: ...ve sensitivity 1Mbps 92 dBm 2Mbps 89 dBm 5 5Mbps 87 dBm 11Mbps 82 dBm Antenna Connector 1 x RP SMA Power Requirements Battery 4 8V 4 celle s 1650mAh NiMh Charger 230 VAC 70 150mAh 3 10 celle s NiCd NimH Physical Characteristics Casing IP65 protection Dimensions WxHxD 117x228x46 24 mm 4 6x8 97x1 82 in Weight 500g 1 1 pound Environmental Limits Operating Temperature 25 to 70 C 13 to 158 F Ambient Re...

Page 19: ... 12 36VDC 220VDC AC Power consumption 3 5W Physical Characteristics Casing IP40 protection Fanless design Dimensions WxHxD 36 5x120x90 mm 1 44x4 72x3 54 in Weight 300g 0 66 pound Installation DIN 35 Rail or wall mounting Environmental Limits Operating Temperature 40 to 85 C 40 to 185 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 0 to 95 non condensing Approvals IEC61000 4 ...

Page 20: ...Frequency 2412 2464 MHz TX Power 15dBm 20dBm EIRP including Antenna RX Sensitivity 90dBm 11Mbps ANTENNA SPECIFICATION Gain 5dBi Omni directional Frequencey 2400 2485 MHz Vertical horizontal BW 25x360 degree Weight 0 5Ibs 0 2Kg Dimension 355x15mm PHYSICAL ELECTRICAL ENVIRONMETNAL Enclosure Size 185x130x50mm Mounting Supports masts up to 3 diameter Weight 1 50kg Enclosure Characteristics Solid Die c...

Page 21: ...C Power supplied to the power supply unit must be 2 or 3 phase Current supplied to the lamp unit must be specific se technical data for specific Type Note Disconnect the power when working on the equipment Electrical equipment must be installed by authorised personnel Check the polarity when connection of 24VDC All Searchlight system equipment MUST BE connected to ground earth Current supplied to ...

Page 22: ...he cable between the power supply and the lamp unit The current can be corrected by use of the wheel on the power supply Powering up By powering up the SCS R50 Searchlight system the panel indicate splashing figure in LED display of the Operating Panel The system starts to search for all units connected to the system After few seconds a specific number of the searchlight in contact will appear in ...

Page 23: ...rchlight position Indicate what position the searchlight is pointing towards 360o Focus Adjustment of the light beam o Focus Narrow beam o Focus Wide beam Vertical speed Adjusts the motor speed vertically in the range from 1 to 15 indicated in LED display Horizontal speed Adjusts the motor speed horizontally in the range from 1 to 15 indicated in LED display Lamp LAMP Lamp on off function Green LE...

Page 24: ...ng screw 1 loosen the positive contact on the lamp 2 and then remove the front Teflon holder 3 Unscrew the bulb from the negative contact In front of the rear Teflon holder Change the bulb and reassemble in reverse order Check the level of Greece and refill when needed in glider for Lamp Holder Check the lamp housing gasket for leakage Recommended intervals not exceeding 6 months Cut the main powe...

Page 25: ... 9 Seal KIT Drum OR OR OR OR OR 10 Cable kit drum OR OR OR OR OR 11 Cable external Xenon OR OR OR OR OR 12 Heat Element Drum 115V 1009135 1009136 12 Heat Element Drum 230V 1009173 1009118 13 Ignitor 230V 1009240 1009239 1009237 13 Ignitor 115V 1009235 1009241 1009236 14 Noise filter kit complete OR OR OR OR OR 20 Gear Complete 115V OR 20 Gear Complete 230V OR 21 Motor Vert 1009224 21 Motor Hor 100...

Page 26: ...26 ...

Page 27: ...27 XS 500 to 3000 R50 5 1 Mechanical Dimensions 6 Drawings ...

Page 28: ...28 Pedestal R50 ...

Page 29: ...29 Operation Panel Main and Slave w cut dimensions ...

Page 30: ...IN1005S 5T or 1 one full duplex fiber port of 100Base FX single mode or multimode and 4 LAN cable entries KEIN1005 1S M 4T Look in the manual for KEIN1005 for more details Installation DIN 35 Rail or wall mounting Power in Plug incl connector Fiber Optic LAN RJ45 connection ...

Page 31: ...31 Power Supply Rectifiers NP 0725 ...

Page 32: ...32 EX 30 G 1 ...

Page 33: ...33 P X50 N C ...

Page 34: ...34 EX 100 D 1 ...

Page 35: ...35 N3 80 N3 100 ...

Page 36: ...36 LAN Cables only 6 1 Ethernet BUS ...

Page 37: ...37 ...

Page 38: ...38 ...

Page 39: ...39 XS500 1000W with integrated Xenon Power Supply 6 2 Electrical XS500 1000W with integrated PSU Built in XENON power supply NP 0725 ...

Page 40: ...40 XS 500 1000W XS 1600 3000W with EX 100 D 1 ...

Page 41: ...41 XS 1600 3000W with N3 80 or N3 150 ...

Page 42: ...42 ...

Page 43: ...43 Xenon Cable overview ...

Page 44: ...J45 with termination points up to 1 5mm2 or WAGO connecting plug RJ45 WAGO connecting adapter Item no 289 175 Product description INTERFACE MODUL FOR ETHERNET RJ 45 CAGE CLAMP CONNECTION for DIN 35 rail Or RJ45 connector Item no 1658435 IP20 CAT5e 4 pos PROFINET with QUICKON fast connection technology for 1 wire and 7 wire conductors AWG 26 22 for cable diameter of 4 5 mm 8 0 mm color gray Cable 2...

Page 45: ...45 Connecting diagram Main and Slave Operation Panel ...

Page 46: ...46 6 3 Internal Wire Diagram XS 500 R50 with integrated PSU ...

Page 47: ...47 XS 500 R50 ...

Page 48: ...48 XS 1000 R50 ...

Page 49: ...49 XS 1600 XS1600 XS2000 R50 ...

Page 50: ...50 XS 3000 R50 ...

Page 51: ...51 N3 80 150 E ...

Page 52: ...52 Owner NOTES ...