24
Warning!
When changing the bulb, use facial protection and leather gloves as accidental breakage of
the glass bulb can critically harm anyone within a radius of 8m.
Note:
Do not touch the bulb with bare hands or with anything greasy.
The bulb must be clean.
Note:
The XBO light bulbs work under high pressure and can explode if not handled
carefully.
Note:
Be ware of a hot bulb!
Do not touch the bulb with bare hands or anything greasy!
The bulb must be clean!
USE eye protection!
Be careful to not damage any parts. Don’t touch the bulb with bare hands. Check the lamp housing gasket for
damages and impurities.
•
Cut the main power to the searchlight.
•
The lamp housing must
not
be opened until at least 10 minutes after the lamp has been turned off or until the
lamp is cooled down. Put on the protection cover including a facial protection
and gloves.
•
In front of the Lamp Holder, first loosen the locking screw (1), loosen the positive contact on the lamp (2), and
then remove the front Teflon holder (3).
•
Unscrew the bulb from the negative contact (In front of the rear Teflon holder).
•
Change the bulb and reassemble in reverse order.
•
Check the level of Greece and refill when needed in glider for Lamp Holder.
•
Check the lamp housing gasket for leakage.
Recommended intervals not exceeding 6 months:
•
Cut the main power to the searchlight!
•
Control of all gaskets and cable glands.
•
Control of all screw and nut connections.
•
Check lamp holder with contact points.
•
Check the level of Grease and refill when needed in glider for Lamp Holder.
•
Reflector and front glass to be cleaned with a soft cloth and ethanol.
•
Tighten all terminal strips in the searchlight junction box.
•
After half burning time of the bulb, remove washer on the negative contact. This allows the bulb to make
a half turn. This is done to rotate the coating built up on top of the bulb.
•
Check the level of Grease and refill when needed underneath the VS120 gasket on the top of the motor
housing.
4.2
Change of the lamp
4.3
General Searchlight Maintenance
Summary of Contents for XENON R50 Series
Page 6: ...6 Main and Slave Operation Panel ...
Page 7: ...7 Wireless Operation Panel ...
Page 11: ...11 1 7 Power Supply Rectifiers ...
Page 26: ...26 ...
Page 27: ...27 XS 500 to 3000 R50 5 1 Mechanical Dimensions 6 Drawings ...
Page 28: ...28 Pedestal R50 ...
Page 29: ...29 Operation Panel Main and Slave w cut dimensions ...
Page 31: ...31 Power Supply Rectifiers NP 0725 ...
Page 32: ...32 EX 30 G 1 ...
Page 33: ...33 P X50 N C ...
Page 34: ...34 EX 100 D 1 ...
Page 35: ...35 N3 80 N3 100 ...
Page 36: ...36 LAN Cables only 6 1 Ethernet BUS ...
Page 37: ...37 ...
Page 38: ...38 ...
Page 40: ...40 XS 500 1000W XS 1600 3000W with EX 100 D 1 ...
Page 41: ...41 XS 1600 3000W with N3 80 or N3 150 ...
Page 42: ...42 ...
Page 43: ...43 Xenon Cable overview ...
Page 45: ...45 Connecting diagram Main and Slave Operation Panel ...
Page 46: ...46 6 3 Internal Wire Diagram XS 500 R50 with integrated PSU ...
Page 47: ...47 XS 500 R50 ...
Page 48: ...48 XS 1000 R50 ...
Page 49: ...49 XS 1600 XS1600 XS2000 R50 ...
Page 50: ...50 XS 3000 R50 ...
Page 51: ...51 N3 80 150 E ...
Page 52: ...52 Owner NOTES ...