The searchlight must be mounted on a horizontal surface using 4 stainless screws.
•
The Main/Slave Operation Panel and the Switch is designed for installation in indoor applications.
•
The Access Point is designed for out side installation.
•
The Rectifier is designed for inside installation.
•
The Main Operation Panel requires 24V DC connected in series with a 1A fuse to the positive (+) conductor.
•
The Switch requires 24V DC. In addition to grounding
•
Depending on The Searchlight model it requires 115V AC or 230V AC.
•
Power supplied to the power supply unit must be 2 or 3-phase.
•
Current supplied to the lamp unit must be specific (se technical data for specific Type).
Note:
Disconnect the power when working on the equipment!
Electrical equipment must be installed by authorised personnel!
Check the polarity when connection of 24VDC!
All Searchlight system equipment MUST BE connected to ground/earth!
Current supplied to the lamp unit must be 65A DC for 1600W, 70A DC for 2000W and 100A for 3000W.
To be able to turn off the searchlight from the main panel, the switch on top of the Power Supply
N3-80 or N3-150 must be in position “0” (Zero). See picture 1
Picture 1:
3
Installation
3.1
Mechanical installation
3.2
Electric installation
Summary of Contents for XENON R50 Series
Page 6: ...6 Main and Slave Operation Panel ...
Page 7: ...7 Wireless Operation Panel ...
Page 11: ...11 1 7 Power Supply Rectifiers ...
Page 26: ...26 ...
Page 27: ...27 XS 500 to 3000 R50 5 1 Mechanical Dimensions 6 Drawings ...
Page 28: ...28 Pedestal R50 ...
Page 29: ...29 Operation Panel Main and Slave w cut dimensions ...
Page 31: ...31 Power Supply Rectifiers NP 0725 ...
Page 32: ...32 EX 30 G 1 ...
Page 33: ...33 P X50 N C ...
Page 34: ...34 EX 100 D 1 ...
Page 35: ...35 N3 80 N3 100 ...
Page 36: ...36 LAN Cables only 6 1 Ethernet BUS ...
Page 37: ...37 ...
Page 38: ...38 ...
Page 40: ...40 XS 500 1000W XS 1600 3000W with EX 100 D 1 ...
Page 41: ...41 XS 1600 3000W with N3 80 or N3 150 ...
Page 42: ...42 ...
Page 43: ...43 Xenon Cable overview ...
Page 45: ...45 Connecting diagram Main and Slave Operation Panel ...
Page 46: ...46 6 3 Internal Wire Diagram XS 500 R50 with integrated PSU ...
Page 47: ...47 XS 500 R50 ...
Page 48: ...48 XS 1000 R50 ...
Page 49: ...49 XS 1600 XS1600 XS2000 R50 ...
Page 50: ...50 XS 3000 R50 ...
Page 51: ...51 N3 80 150 E ...
Page 52: ...52 Owner NOTES ...