18 / 56
MA120527=>2012-05
EasyLift 500 / Sesam 600
Installation must be performed by qualified service
technicians.
Work on the electrical installation must only be carried out by
authorised specialist personnel.
The load capacity and suitability of the supporting
construction of the building in which the door operator is to be
installed must be inspected and approved by an expert.
The door operator must be fully and securely attached at all
fastening points. All fastening materials must be selected
according to the nature of the supporting construction and
they must be able to withstand traction force of 900 N.
In the event of non-conformance with these
requirements, there is a risk of injury and material
damage caused by a falling operator or an uncontrolled
movement of the door.
When drilling the fastening holes, do not damage the building
structure or any electrical, water or other lines.
After lifting up the door operator to the ceiling, fasten it fully
with appropriate tools to prevent it from falling down.
Please observe appropriate industrial safety regulations and
keep children away during installation.
The door operator has the following safety devices. Do
not remove them or alter their functionality.
• Automatic load switch-off during functions "OPEN" and
"CLOSE"
• Connection for light barrier / safety edge / optosensor
• Emergency lock release (see page 15 (N)
Checking Load Switch-off
The automatic load switch-off is a clamping and safety
mechanism that is designed to prevent accidents due to a
moving door.
Stop the door from outside with both hands at waist height.
When closing:
The door must stop automatically and reverse a little if it
comes into contact with an obstruction.
When opening:
The door must stop automatically if it comes into contact with
an obstruction.
Emergency Lock Release
Check as per the information provided on page 15 (N).
Additional Safety Devices
Check for proper functioning as per the manufacturer’s
instructions.
Signals of the indicator lamps 1 to 3
Please note:
Check that the door is working properly
and running smoothly, and adjust if necessary. The
spring tension of the door must be set in such a way that it is
stable and can be opened and closed by hand smoothly and
without jolting.
• Standard and appropriate
shock-proof sockets approx. 10
- 50 cm near the fastening point at the head of the operator.
• Only install the door operator in dry garages.
See instructions for installation from page 9.
Once installation is complete
• connect the door to the door operator by: slowly opening
the door by hand until you hear the slide snap in.
• Connect to the mains, LED 1 (red) flashes.
• Teach in the door operator (see Chapter 15).
• Teach in the remote transmitter (see Chapter 16).
• Carry out a safety inspection (see Chapter 9).
7 Installation Precautions
8 Safety devices of the Door Operator
9 Safety Inspection
10 Controls and Indicators
1
LED 1
2
LED 2
3
LED 3-6
10 POWER button
11 PROG button
12 CANC button
13 TEST button
3
Set force tolerance
1 + 2
Status during programming
11 Connections
4
Antenna
5+6 External switch
7-9 Light barrier
12 Installation Preparations
13 Installation
14 Commissioning
Summary of Contents for EasyLift 500
Page 2: ......
Page 9: ...EasyLift 500 Sesam 600 MA120527 2012 05 9 56 A Lieferumfang ...
Page 22: ...22 56 MA120527 2012 05 EasyLift 500 Sesam 600 A Scope of delivery ...
Page 35: ...EasyLift 500 Sesam 600 MA120527 2012 05 35 56 A Fournitures ...
Page 48: ...48 56 MA120527 2012 05 EasyLift 500 Sesam 600 A Leveransomfattning ...