8.4. Status Byte

Error/fault

Possible cause

Troubleshooting measure

-Output flow too low or not proportional

- Connection cross section too small

-Check and enlarge if necessary

-no control / maximum flow only 

- Supply voltage missing/too low

- Check voltage and ensure if necessary , check for 

current limitation

- no output flow

- no setpoint is present
-no supply pressure
-pneumatic connections clogged
- pneumatic connection 

- measure the input signals
- check
- check
- check according to the book

- Fluctuations in the output flow

- Fluctuations in supply pressure

- Diagnosis of the pressure supply

- No reaction of the output flow when the setpoint value 

is changed

- Valve mechanics dirty / damaged

- Check filtering and send in device for maintenance

- Output flow is reached only sluggishly

- Use of compressed air that has not been cleaned or 

lubricated
- Dirt in the valve causes friction

- use unlubricated compressed air and install oil filter 

or suitable FRL unit
-Check filter

- Abrupt change of the flow

- Disturbances in the input signal or in the supply
- Insufficient shielding of the setpoint signal or the ground 

connection

- Installation Improve / Shield
- Improve ground wiring

- Flow rate at setpoint in middle position too high / not 

as expected

- Faulty mass connection when using the diffential voltage 

input.
- Internal leakage due to contamination

- Correct the wiring of the system
- Have valve serviced

Summary of Contents for VP60 Series

Page 1: ...This manual contains proprietary information No part of this publication may be reproduced transcribed or transmitted in any form without the written consent of the publisher Every e ort has been mad...

Page 2: ...1 8 Troubleshooting and Diagnosis 12 9 Transport and Storage 15 10 Disposal 15 11 Appendix 16 This document as well as the data specifications and other information presented in it are the sole proper...

Page 3: ...tes a potentially dangerous situation that may result in death or serious injury if not avoided CAUTION This combination of symbol and signal word indicates apossibly hazardous situation that may resu...

Page 4: ...ity for any damage incurred Caution This product is for use in industrial compressed air systems only It is to be used where the pressure and temperature ratings listed in the data sheet are not excee...

Page 5: ...face or the IO Link parameters Use suitable stop and vent valves in the supply lines and at the consumer connections for enabling Warning Danger from compressed air Connections 2 4 can still be under...

Page 6: ...adjustable proportional zero cut characteristic is maintained in any case When de energised or in the event of faults see valve operating states a spring presses the spool into the preferred position...

Page 7: ...he following sub functions result 2 2 NC normally closed The air is connected to port 2 ports 3 4 and 5 are closed Via VP Tool the entire setpoint range can be assigned to the 2 2 valve function with...

Page 8: ...g 2 3 1 A filtering of the supply air 3 microns is strongly recommended For flow intensive applications screw fittings with a straight outlet should be preferred in order to avoid possible pressure lo...

Page 9: ...ctrical devices must be observed The valve body must always be integrated into the equipotential bonding of the plant grounding Pin Colour Typ Ref Port size 1 white Iin Setpoint input current 4 20 mA...

Page 10: ...its often have an electronic current limiter the activation of which results in a reduction of the output voltage As a result the switch off threshold of the actuator of the VP60 of 18 V can be unders...

Page 11: ...lines and additional valves should have a nominal size larger NG10 than the VP60 NG8 and be as short as possible 7 1 General Safety Instructions 7 2 Installation 7 3 Accessories Note For dynamic appl...

Page 12: ...ogue Version 8 1 2 IO Link Version LED STATUS red Valve system fault check overvoltage at if necessary green The position control of the valve piston is active IOL Flashed green IO Link Communications...

Page 13: ...oo much Check that a voltage 18V is applied to VA 0b00000010 Overcurrent in actuator The current monitoring of the actuator unit has detected a too high current consumption The valve may be sluggish o...

Page 14: ...tuations in the output flow Fluctuations in supply pressure Diagnosis of the pressure supply No reaction of the output flow when the setpoint value is changed Valve mechanics dirty damaged Check filte...

Page 15: ...e damaged by transport corrosion or penetrating foreign bodies Transport the valve in the delivery packaging Do not throw or drop packages Do not remove the valve from its packaging until immediately...

Page 16: ...of continued research and development We therefore reserve the right to amend without notice the specifications given in this document 11 Annex 11 1 Component View 11 2 Dimensions Connector Protectiv...

Page 17: ...exemplary The nameplate contains the following information Manufacturer Connection schemes Model Identification number with version Pressure range Inlet pressure p1 Setpoint W Actual value X Flow Sup...

Page 18: ...0 1023 2047 100 90 80 70 60 40 50 30 20 TCF Fellbach 2021 018 03 21 VP60 Analogue IO Link Our policy is one of continued research and development We therefore reserve the right to amend without notice...

Page 19: ...one of continued research and development We therefore reserve the right to amend without notice the specifications given in this document Flow rate as a function of the set point at constant pressure...

Page 20: ...without notice the specifications given in this document Please for Technical Data see Data Sheet Frequency response and phase of the slider position controller at 10 50 and 100 setpoint Flow rate as...

Page 21: ...ation and parameter addresses can be found at https www norgren com de de technical service software 11 6 IO Link General Information 11 7 IO Link Process Data 11 8 Important IO Link Parameters Name B...

Page 22: ...China Czech Republic Germany India Mexico UK and the USA For information on all Norgren companies visit www norgren com Supported by distributors worldwide Norgren Buschjost FAS Herion Kloehn Maxseal...

Reviews: