16
T4BE-042KA SERIES
SUCT.
PRESS.
OUTDOOR TEMPERATURE (°F)
70
75
80
85
90
95
100
105
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
132
226
132
134
231
133
250
136
136
235
134
254
137
273
140
138
240
135
258
138
277
141
297
144
140
242
135
262
138
281
141
300
145
320
148
142
265
139
284
142
303
145
323
148
343
152
144
288
143
307
146
326
149
345
152
365
156
146
310
146
329
149
348
152
368
156
388
160
148
314
147
333
150
352
153
370
156
390
160
150
337
150
356
153
375
157
392
159
152
360
154
379
157
398
160
154
384
158
402
161
156
407
161
158
Table 9. Charging Table for 3.5 Ton Models
(Restrictor Matches)
T4BE-048KA SERIES
SUCT.
PRESS.
OUTDOOR TEMPERATURE (°F)
70
75
80
85
90
95
100
105
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
132
248
128
134
248
128
269
133
136
248
128
269
133
290
137
138
248
128
269
133
290
137
310
141
140
249
129
269
133
290
137
311
141
331
146
142
270
133
290
137
311
141
332
146
352
150
144
291
137
311
141
332
146
353
150
373
155
146
312
141
332
146
353
150
373
154
394
159
148
312
141
332
145
353
150
374
154
394
159
150
333
145
353
150
374
154
395
158
152
354
150
374
154
395
158
154
375
154
395
158
156
396
158
158
Table 10. Charging Table for 4 Ton Models
(Restrictor Matches)
Shaded boxes indicate flooded conditions.
Rated design values. The suction pressure will vary from design value if indoor air flow, entering dry
bulb, or entering wet bulb temperatures are lower than design.
1. All pressures are listed in psig and all temperatures in ° F
2. Discharge temperatures greater than charted values indicate an undercharged system.
3. In Cooling Mode, suction pressure will be lower than design value if indoor air flow, entering dry bulb, or entering
wet bulb temperatures are lower than design.
4. In Heating Mode, charge should be weighed in. It is strongly recommended to verify charge in cooling mode
at ambient above 70°F.